Summary of Contents for MBE-R

Page 1: ...MBE R ES EN FR IT...

Page 2: ...2 90 45 0 45 0 MBE R...

Page 3: ...z KM10 Q1 L N 1 2 3 4 24 or 230Vac 50Hz KM10 KM1 MBE R 1 2 4 3 5 6 7 4 3 MBE R 1 230V 50 60Hz MBE R 2 400V 50 60Hz 60 C 120 C L2 N PE 2 400V 50Hz KM10 Q1 L1 L2 1 2 3 4 L1 24 or 230Vac 50Hz KM10 KM1 MB...

Page 4: ...3 MIN MAX INT EXT PCB 12 PCB 11 PCB 10 PCB 9 PCB 8 PCB 7 PCB 6 PCB 5 PCB 4 PCB 3 PCB 2 PCB 1 10 11 8 9 INT EXT 8a INT EXT 8b MBE R 3 400V 50 60Hz MBE R PCB Img 3 Img 4 60 C 120 C L3 N PE 24 or 230Vac...

Page 5: ...0 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX D P INT EXT 12 MBE R TGK 330 8 Img 5 Img 6 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX D P 1 2 3 INT E...

Page 6: ...25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX D P 1 2 INT EXT 12 MBE R TGK 330 TGR 530 8 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX D P 1 2 3 4 INT EXT 12...

Page 7: ...2 21 22 23 MIN MAX D P INT EXT 12 8 0 1 2 3 4 5 6 7 8 9 10 0 25 25 50 75 100 Pout Ureg V U reg GND 13 20 25 30 35 40 45 50 0 5 10 15 20 25 30 1 2 3 4 5 6 7 8 9 10 11 12 21 22 23 MIN MAX INT EXT 8 0 1...

Page 8: ...a de dos veces el di metro No utilizar estas bater as en atm sferas explosivas o co rrosivas La temperatura m xima del aire ambiente alrededor de la bater a no debe superar los 35 C No instalar las b...

Page 9: ...aro marcha bater a ventilador 2 Temporizaci n post ventilaci n 3 Rel bater a 4 Rel ventilador 5 Dispositivo de corte omnipolar con distancia entre contactos de al menos 3 mm 6 Rearme autom tico 7 Rear...

Page 10: ...attery respecting the air ow direction indicated by the arrow located on the battery Use the batteries only for heating clean air If the heating elements become dirty there is a risk of re We recom me...

Page 11: ...e 35 C Minimum air velocity 1 5 m s INDEX FOR WIRING DIAGRAM Ref Description 1 General ON OFF switch heater and fan 2 Post ventilation timer 3 Heater relay 4 Fan relay 5 The electrical installation mu...

Page 12: ...ie L utilisation d un ltre air en amont de la batterie est recommand e Respecter une distance minimale de deux fois le diam tre entre le l tre et la batterie lectrique Ne pas utiliser la batterie lect...

Page 13: ...ription 1 Marche Arr t batterie ventilateur 2 Temporisation post ventilation 3 Relais batterie 4 Relais ventilateur 5 Dispositif de coupure omnipolaire ayant une distance d ouverture des contacts sup...

Page 14: ...a parte della rete del condo tto in cui possa prodursi condensa Il collegamento elettrico deve prevedere un dispositivo di controllo della portata d aria La batteria di riscaldamento opera solamente q...

Page 15: ...ntilatore 5 Interruttore bipolare con distanza tra i morsetti di almeno 3 mm 6 Riarmo automatico 7 Riarmo manuale 8 Correzione interna o esterna del setpoint della temperatura 8a Correzione interna Po...

Page 16: ...S P SISTEMAS DE VENTILACI N S L U C Llevant 4 Pol gono Industrial Llevant 08150 Parets del Vall s Barcelona Espa a Tel 34 93 571 93 00 Fax 34 93 571 93 01 www solerpalau com Ref 1441345 1...