Ventilation unit with heat recovery

DUOVENT

®

 COMPACT DV

 

3

 

1. GENERAL

1.1 INTRODUCTION

 

This manual is intended for ventilation units with heat recuperation DUOVENT

®

 COMPACT DV. Its purpose is to provide as much information as 

possible for the safe installation, commissioning and use of this equipment. Due to the fact that our products are constantly evolving, we reserve 
the right to change this manual without prior notice.

 

1.2 WARRANTY

 

We do not guarantee the suitability of the devices for special purposes, the determination of suitability is fully in the competence of the customer 
and  the  designer.  The  warranty  for  the  devices  is  in  accordance  with  valid  legal  regulations.  The  warranty  is  only  valid  if  all  installation  and 
maintenance instructions, including protection, are observed. The warranty covers manufacturing defects, material defects or malfunctions of the 
device.

 

The warranty does not cover defects caused by:

 

 

 

 

 

 

 

 

 

 

 

 

 

I

mproper use and design

I

mproper handling (does not apply to mechanical damage)

D

uring transport (compensation for damage caused during transport must be claimed from the carrier)

I

ncorrect installation, incorrect electrical connection or protection

I

ncorrect operation

U

nprofessional intervention in the device

D

isassembling the device

U

se in unsuitable conditions or in an unsuitable manner

W

ear and tear caused by normal use

T

hird party intervention

D

ue to a natural disaster

F

rost-damaged water exchanger parts are not covered by the warranty if it has been demonstrably proven that the unit was

in operation without heating water at min. design temperature or during shutdown of the boiler circuit

 

When claiming the warranty, it is necessary to submit a report containing:

 

 

 

 

 

 

 

 

 

 

D

ata on the complaining company

D

ate and number of the sales document

E

xact specification of the defect

W

iring diagram and fuse details

M

easured values when starting the device

V

oltage

C

urrent

A

ir temperature

A

ir flow

The warranty repair is carried out in principle at the discretion of S&P UK Ventilation Systems 

Ltd 

at the company's service centre or at the 

installation site. The method of eliminating the defect is solely at the discretion of the service company S&P UK Ventilation Systems

 

Ltd. 

The 

complaining party will receive a written statement on the result of the complaint. In the event of an unjustified complaint, the complaining

 

party 

pays all costs of its implementation.

Warranty conditions

 

The device must be installed by a professional air handling service company. 

DUOVENT

®

 COMPACT DV, incl. control system DVAV, DCAV, 

DCOP, must be commissioned only by the Seller or by the person authorised by the Seller. Failure to comply with this condition will 
result in the termination of the Buyer's rights from defective performance and from the Quality Warranty. Detailed terms are specified in 
the Seller's Complaint Procedure. 

The electrical connection must be made by a specialist electrical company. Installation a nd location of 

the 

device must be unconditionally performed in accordance with ČSN 33 2000-4-42 (IEC 364-4-42). The device must be subjected to an initial 
electrical inspection according to ČSN 33 1500. 

The device must be regulated to the designed air-conditioning parameters.

 

When starting 

the device, it is necessary to measure the above-specified values and make a record of the measurement, confirmed by the company putting the 
device into operation. In the event of a complaint about the equipment, it is necessary to submit a record of the above- mentioned parameters 
from commissioning together with the declaration protocol together with the initial revision, which the operator acquires within the commissioning 
and maintenance of the electrical installation.

 

During the operation, it is necessary to perform regular inspections of electrical equipment within the deadlines according t

o ČSN 33 1500 and 

inspection, maintenance and  cleaning of  air-conditioning equipment. It  is necessary to  keep a  "Maintenance and inspection book" for  the 
maintenance and service of the device, for which the device operator is responsible.

 

When taking over the device and unpacking it from the transport packaging, the customer is obliged to perform the following inspections. It is 
necessary to check the integrity of the device, as well as whether the delivered device exactly agrees with the ordered device. It is always 
necessary to check whether the label and identification data on the transport packaging, equipment or engine correspond to the designed and 
ordered parameters. Due to the continuous technical development of the equipment and changes in technical parameters reserved by the 
manufacturer, and the time lag between the project and the implementation of own sales, fundamental differences in the parameters of the 
equipment at the date of sale cannot be ruled out. The customer is obliged to inform the manufacturer or supplier about such changes before 
ordering the goods. Subsequent complaints cannot be taken into account.

 

www.solerpalau.co.uk

 

Summary of Contents for DUOVENT COMPACT DV

Page 1: ...INSTRUCTION MANUAL www solerpalau co uk DUOVENT COMPACT DV Ventilation unit with heat recovery...

Page 2: ...n Connection of electric heater Connection of water heater Connection of water cooler Connection of direct evaporator Connection of condensate drain Bypass and mixing flap Inlet and outlet flap 5 2 10...

Page 3: ...ation Warranty conditions The device must be installed by a professional air handling service company DUOVENT COMPACTDV incl controlsystemDVAV DCAV DCOP must be commissioned only by the Seller or by t...

Page 4: ...hat could affect safety and proper function are prohibited Installation and operating documentation must be available to the operator and service It is advisable to place it close to the installed uni...

Page 5: ...nit for ventilation of pool halls Order examples DUOVENT COMPACT DV 3000 DI DX MX KL G4 F7 F7 DVAV JH2 Unit size 3000 with electric heater direct evaporator bypass and mixing flap two stage filtration...

Page 6: ...INSULATION OF THE ANTIFREEZE PROTECTION CONTACT SENSOR WARNING DO NOT OPERATE THE UNIT WHILE CONSTRUCTION WORK IN PROGRESS AIR FLOW CALCULATION PLATE LOCATED AT FAN SUCTION PRESSURE ORIFICE PORT WARNI...

Page 7: ...0 182 DUOVENT DV 1200 521 992 312 80 2091 260 5 260 5 582 300 500 DUOVENT COMPACT DV 500 to 1200 under ceiling arrangement positions xH AH unit position drawn UNIT BOTTOM VIEW Exchanger outlets UNIT T...

Page 8: ...2 X3 L Y D Y Exchanger outlets D 20 D 1 2 1 2 DETAIL OF CONNECTING FLANGE INTEGRATED IN WALL PANEL 19 18 18 18 Condensate drains 152 152 152 21 www solerpalau co uk 40 A 150 B A B 150 F 157 42 42 X1 X...

Page 9: ...94 694 694 627 627 694 694 694 694 694 1085 1085 1085 1085 1085 1085 1085 DUOVENT COMPACT DV 1800 to 7800 floor arrangement positions xP AP unit position drawn X3 X1 X2 X E E X 1 2 1 2 19 18 18 18 Tra...

Page 10: ...00V 50Hz 3000 1238 927 1 8 1 4 89 1 3500 320 387 3000 DCA DCC 3000 DCA DX 21 8 21 8 21 3 21 3000 DI 15 22 4200 4200 DCA 4200 DCB 4200 DCA DCC 4200 DCA DX 4200 DI 29 8 22 30 2 20 5 29 8 3 400V 50Hz 420...

Page 11: ...ES EXCHANGER OUTLETS ETC Ensure proper balancing of the transported unit The ropes above the unit must be stretched to prevent damage The outdoor variants of the units are fitted with transport profil...

Page 12: ...is necessary to check the insulation of the HVAC piping in parts with a risk of condensation Condensate formed in the air duct can in unfavourable conditions spill into the interior of the unit where...

Page 13: ...tion box 5 1 2 HOW TO STORE THE UNIT AT THE DESTINATION The unit is designed for floor mounting in a vertical position positions marked xV in the unit code or horizontal position positions marked xP i...

Page 14: ...applicable regulations The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving or live part DUOVENT COMPACT DV units comply with...

Page 15: ...let and outlet ports with respect to the position of the exchanger connection pipes Neck variants vertical arrangement viewed from unit operation side INLET OUTLET OUTLET INLET OUTLET OUTLET INLET INL...

Page 16: ...TLET OUTLET www solerpalau co uk INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET...

Page 17: ...INLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET INLET OUTLET OUTLET OUTLET INLET INLET INLET OUTLET OUTLET OUTLET OUTLET INLET INLET INLET...

Page 18: ...n it is exceeded the operating thermostat opens and switches off the heater after cooling below 60 C the heater automatically switches on again Location of the release button under the cover on the un...

Page 19: ...nger connections it is necessary for example to hold the heat exchanger neck with a second wrench so that the tightening torque is not transmitted to the heat exchanger body Table of dimensions of wat...

Page 20: ...n screws on the heat exchanger collectors The heat exchanger can then be disconnected from the heating water distribution system and removed from the unit Max operating water temperature of water heat...

Page 21: ...the cooler must be vented after connecting and filling the system with cooling water The vent screws are located directly at the heat exchanger connection necks The vent screws are accessible either...

Page 22: ...specialist company It is mandatory to perform a Refrigerant leak test on the refrigerant circuit This test is performed only by a technician with the appropriate authorization according to the law 5 2...

Page 23: ...ING FLAP In the basic version each unit is equipped with a bypass flap of the plate heat exchanger BP The bypass is used for summer ventilation defrost control of the recuperation exchanger in the eve...

Page 24: ...on mode Location of mixing and bypass flap for DUOVENT 500 800 1200 units with MX mixing mode www solerpalau co uk ETA flap Mixing flap MX ODA flap Bypass flap BP Circulation flap C part 1 ODA flap Ci...

Page 25: ...uators 5 2 10 BASIC ACCESSORIES 5 2 10 1 CONDENSATE DRAIN TRAPS Condensate traps must be ordered as a separate item as they are not included with the unit Vacuum type siphon scheme SF P 300 bottom edg...

Page 26: ...ected piping Mixing units should be mounted on separate hinges using heating sleeves on the wall pipes or on an auxiliary structure When placed under the ceiling it is necessary to maintain control an...

Page 27: ...I C control system to the electrical distribution network is made by a separate supply cable which is not part of the delivery of the device www solerpalau co uk Ventilation unit with heat recovery DU...

Page 28: ...ts according to the set parameters in the automatic summer winter mode according to the outdoor temperature and time dependencies Manual mode selection is also possible The heater can be hot water con...

Page 29: ...otation of the fans the correct phasing of the damper actuators and mixing valves If the unit is equipped with a Digireg control system directly from the factory a SETPACK test package has been perfor...

Page 30: ...onnection to distribution lines Closing of all doors and service holes Any faults must be rectified before starting the unit for the first time 7 2 TRIAL OPERATION The material content of the comprehe...

Page 31: ...applicable regulations The device must be installed in such a way that under normal operating conditions it cannot come into contact with any moving or live part DUOVENT COMPACT DV units comply with t...

Page 32: ...NH IH2 JH2 MH2 NH2 263 295 263 365 KH LH OH PH KH2 LH2 OH2 PH2 263 295 263 295 1200 1200 all positions 420 365 365 420 ETA filter size ETA mm ODA filter size ETA mm Size of DUOVENT DV Vnom m3 h Neck...

Page 33: ...replace the entire unit or fan open the door by opening the locks by turning 90 The fan is located on rubber silent blocks Loosen the 4 nuts lift and remove the fan as shown in the following figure K...

Page 34: ...nitor the implementation of the measures taken Check the siphons for condensate drainage especially their permeability and tightness especially the tightness of the mounting on the unit and the tightn...

Page 35: ...l applicable standards and national and local building standards IF CLAIMING UNDER WARRANTY Please return the completed product carriage paid to your local authorised distributor All returns must be a...

Reviews: