21
Filter timer settings:
It is possible to set the timing to 6, 9, 12 or 15 months (9 months factory setting). Fouling is linked to the
external environment (pollution, pollen,..) and the use of housing (dust, cooking fats..). It is advisable to
modify this parameter after the second alarm. Of course, after the installation, the extract air is dusty
and not representative of a normal conditions. During the second filter check, if you notice that the
filters are clean you can increase the time (12 or 15 months). However, if you notice that the filters are
very dirty, you should decrease the time (6 months).
To modify the filter alarm timing:
1. - Open the remote control box.
2. - Set the micro contacts 1 and 2 by the number of months to suit your installation.
6 months
9 months
(Factory settings)
12 months
15 months
Filter Alarm Timing
6
–
SWITCHING ON THE DOMEO
To start your DOMEO unit use the following process:
1. Verify that all system components are correctly installed and connected:
•
Fresh air intake duct insulated and connected correctly (Do not use a fresh air intake
equipped with insect screen)
•
Fresh air and exhaust ducts insulated and connected correctly
•
Fresh air and exhaust vents connected
•
Flow regulators mounted in the right direction (if installed)
•
Air outlet using insulated duct and connected to the outside (Using a roof cowl or outlet
without an insect screen)
•
Insulated flexible ducts taut and large radius bends (if installed)
•
Check that the unused spigots on plenums are sealed (if installed)
•
Condensation drain well connected (siphon)
•
Check that all connections are sealed (on the DOMEO, on plenums and valves)
•
Check the setting of the power circuit breaker
2. Turn on the DOMEO
3. Adjust the parameters as shown in paragraph 5.1 a.