SanDisk CompactFlash Card OEM Product Manual
ATA Command Description
Table 5-24 defines the valid extended error codes for the CompactFlash Memory Card Series
product. The extended error code is returned to the host in the Error Register. This command
must be the next command issued to the card following the command that returned an error.
Table 5-24
Extended Error Codes
Extended Error Code
Description
00h
No error detected
01h
Self test OK (no error)
09h
Miscellaneous error
20h
Invalid command
21h
Invalid address (requested head or sector invalid)
2Fh
Address overflow (address too large)
35h, 36h
Supply or generated voltage out of tolerance
11h
Uncorrectable ECC error
18h
Corrected ECC error
05h, 30-34h, 37h, 3Eh
Self test or diagnostic failed
10h, 14h
ID not found
3Ah
Spare sectors exhausted
1Fh
Data transfer error/aborted command
0Ch, 38h, 3Bh, 3Ch, 3Fh
Corrupted media format
03h
Write/erase failed
5.1.17
Seek–7XH
This command is effectively a NOP command to the card although it does perform a range
check of cylinder and head or LBA address and returns an error if the address is out of range.
Table 5-25
Seek
Bit
7
6
5
4
3
2
1
0
Command (7)
7XH
C/D/H (6)
1
LBA
1
Drive
Head (LBA 27-24)
Cyl High (5)
Cylinder High (LBA 23-16)
Cyl Low (4)
Cylinder Low (LBA 15-8)
Sec Num (3)
Sector Number (LBA 7-0)
Sec Cnt (2)
X
Feature (1)
X
© 2007 SanDisk Corporation
5-19
Rev. 12.0, 02/07
Summary of Contents for CompactFlash Extreme III
Page 2: ......