Sandia 80-2500 Safety, Operation And Maintenance Manual With Parts List Download Page 8

(8) Sniper 12-Gallon, 500 PSI Carpet Extractor

Sniper 12-Gallon, 500 PSI Carpet Extractor (17)

4.0   Set-Up and Operation

4.1   Attach the Power Cord

The machines comes with two (2) 25-foot, 12/3-gauge safety power cords.
•  Locate the pigtail on the back of the machine’s base.
•  Plug the lighted end of the power cord into the pigtail. 
•  Plug the cord into a 20 AMP grounded wall outlet. 
20 AMP circuits are normally found in kitchens and bathrooms. Never remove the ground 

prong from the plug. If a circuit breaker trips during operation, turn machine off, reset the 

breaker and move the electrical cord to a different outlet and resume operation.

4.2    Vacuum System

The extractor uses a dual vacuum motor system that provides outstanding water lift and 

air flow. 

Vacuum Float Assembly Warning System:

The float assembly shut-off, located in the recovery tank on the vacuum stand pipe, 

prevents the waste tank from overflowing into the stand pipe and damaging the vacuum 

motor. The float assembly will cut-off vacuum to the waste tank. The motor will also 

reach a fast, high-pitched sound alerting you when the recovery tank is about to over 

flow. When this happens, immediately turn off the vacuum motor and empty the waste 

tank. If the operator continues to use machine after the tank is full, it will VOID the 

Warranty.

 

The float assembly has a filter to prevent debris from entering the stand pipe. Refer to the 

“Maintenance” section for removal and proper cleaning. It is also necessary to use low 

foaming chemicals or a defoamer to eliminate foam build-up in the recovery tank and 

damage to the vacuum motors.
If moisture enters the vacuum motors, contact an authorized service center. To prevent 

moisture from damaging the vacuum motors during storage, empty the recovery tank and 

store with the lid open.

4.3    Pump System

500 PSI model extractors have self-priming pumps. There is no need to prime this pump.

5.0   Maintenance

WARNING: Disconnect electrical power cord before performing any service or 

maintenance inside the machine base or before testing or repairing switches or power 

cords. Failure to do so may result in severe personal injury or death. 
Regular maintenance is required to keep your Carpet Extractor in proper working 

condition. Failure to properly maintain your machine could void warranty. Thoroughly 

clean all equipment and accessories after each use:
•  Rinse the solution and recovery tanks with clean water.
•  Flush the pump system with clean water, including all hoses and wands.

11.0   Machine Parts List – No Heater

Drawing No. Item ID

Item Description

Qty.

1

SN-12-ST-USIBLU

12-Gallon Solution Tank - Ultimate Blue

1.00

2

Part of Solution Tank

Insert Molded into Solution Tank

1.00

3

80-0017

Bulkhead Fitting

1.00

4

Part of 80-0017 Bulk Head Fitting

1.00

5

10-0846

1/4” MPT Hex Nipple

1.00

6

10-0845

1/8” Strainer

2.00

7

80-0080-UN

500 PSI Regulator / Unloader

1.00

8

80-0026

3/8” Barb x 1/4 MPT 90 Degree

3.00

9

10-0826

3/4” Hose Clamp

5.00

10

80-0001

Extractor Exhaust Hose

0.40

11

80-0003-A

1-1/2” Black Lined Gray Hose

2.00

12

10-0806

1-1/2” Grey Hose Barb Fitting

1.00

13

Bracket

Part of 80-0016 Pump

1.00

14

80-0006

45 Degree Street Elbow

1.00

15

80-0011

90 Degree Street Elbow

1.00

16

10-0803

Splash-proof Switch

3.00

17

80-0059

500 PSI Gauge

1.00

18

80-0013

500 PSI Switch Plate

1.00

19

Connector

Part of 80-0059 Gauge

1.00

20

SN-12-L-USIBLU

12-Gallon Lid - Ultimate Blue

1.00    

21

80-0010

1/4” Brass Tee

2.00

22

80-0011-2 

90 Degree Street Elbow

1.00

23

80-0004

1/4” x 4” Brass Nipple

1.00

24

10-0852

1/4” 90 Degree Brass Elbow

3.00

25

10-0804-A

Hatch Cover Gasket

1.00

26

10-0804

Hatch Cover

1.00

27

80-0012 

Float Assembly

1.00

28

10-0416-A

1-1/2” Black ABS Stand Pipe

1.30

29

80-0008

1.5 PVC Female Adapter

1.00

30

SN-12-RT-USIBLU

12-Gallon Recovery Tank – Ultimate Blue

1.00

31

10-0805

Dump Valve for Extractor

1.00

32

10-0849

1-1/2” ABS Fitting

1.00

33

10-0155

Hose Cuff Straight

1.00

34

10-0848-B

1-1/2” 90 Degree ABS Street Elbow

3.00

35

10-0833

Motor Manifold Bolts

6.00

36

80-0116

Spacer for 3-Stage Extractor Motor Only

6.00

37

80-0811

2-Stage Extractor Motor

2.00

37

10-0810

3-Stage Extractor Motor

2.00

38

10-0838-A

Complete Pigtail  (1 or 2 Depending on Model) 1.00/2.00

39

10-0850

Strain Relief for Pigtail - Part of 10-0838-A

1.00/2.00

39

10-0851

Strain Relief Nut for Pigtail - Part of 10-0838-A 1.00/2.00

40

10-0822

Exhaust Grate

3.00

41

10-1030-S2

2-Stage Extractor Motor Gasket

2.00

41

10-1030-S3

3-Stage Extractor Motor Gasket

2.00

42

SN-12-MFLD

Extractor Motor Manifold

2.00

43

10-0830

Hinge Keeper

1.00

44

10-0821

Extractor Hinge

2.00

45

10-0820

End Cap for Rod on Extractor

2.00

46

SN-12-MD-BLKGRAN

12-Gallon Motor Base – Black Granite

1.00

47

10-0836

19” Axle

1.00

48

10-0807

Wheels

1.00

49

10-0834

Pump Flat Washer 

18.00

Summary of Contents for 80-2500

Page 1: ...d Accessories Sandia Products warrants the roto molded body to be free from defects in material and workmanship under normal use and service for a lifetime Sandia Products warrants the motors to be fr...

Page 2: ...os aspx Machine Features and Benefits www sandiaplastics com featuresVideos aspx Questions or Comments Phone 714 901 8400 Toll Free 800 983 5834 Fax 714 901 8404 Ultimate Solutions Corporate Offices 1...

Page 3: ...tic Drawing No Heater 16 11 0 Machine Parts List No Heater 17 12 0 Machine Schematic Drawing Heated Unit 19 13 0 Machine Parts List Heated Unit 20 Please fill out the following information Model No Se...

Page 4: ...Any use of any other parts will void warranty The manufacturer does not reimburse for parts used by client that were not supplied directly for the machine under warranty The client must contact the ma...

Page 5: ...to maintain safety and to protect your limited warranty Always turn OFF the carpet extractor before connecting disconnecting or working on the machine This equipment must be connected to a properly gr...

Page 6: ...such as gasoline or use in areas where they may be present DO NOT use where oxygen or anesthetics are used DO NOT put objects into openings or use with any openings blocked Keep free of dust lint hair...

Page 7: ...on carpet and agitate carpet Next use clean water from solution tank to extract this procedure is highly recommended Note read and mix your pre spray solution to the dilution ratios as directed Be sur...

Page 8: ...could void warranty Thoroughly clean all equipment and accessories after each use Rinse the solution and recovery tanks with clean water Flush the pump system with clean water including all hoses and...

Page 9: ...VOID your warranty If debris builds up on this filter it will reduce the vacuum air flow and may cause a significant decrease in the rate of water recovery If debris prevents the float ball from movin...

Page 10: ...th this procedure make sure both the power cords are disconnected To examine the filter open the solution tank lid on the front of the machine The filter is in the bottom of the solution tank Grasp th...

Page 11: ...llow the directions on the bottle DO NOT leave CLR in the machine s lines and flush thoroughly CLR may corrode the machine s components and VOID your warranty If you choose to use vinegar you MUST dil...

Page 12: ...ont of the machine Use the wand to spray the mixture into a bucket Vacuum the excess mixture out of the solution tank and into the recovery tank Dispose of the antifreeze properly To return to service...