3.10.2  TEMPERATURE UNIT

If the optional OAT probe is installed, this page changes the Temperature display to the pilot between 
Fahrenheit and Celsius.  All Temperature functions will be set to the selected unit.

Rotate the Data knob unit the Temperature Unit page is displayed.

2.  Rotate the Select knob counter clockwise to select Celsius and clockwise to select Fahrenheit.

3.10.3  ICING ALERT TEMP

If the optional OAT probe is installed, this page selects the temperature at which the Icing Alert Icon is 
displayed.

1.  Rotate the Data knob until the Icing Alert Temp page is displayed.

2.  Press the Enter Pushbutton.  This extinguishes the brackets and alert temp will be blinking.

3.  Rotate the Data knob until the desired Icing alert Temp is displayed.  The set range is 32

o to 41o 

F or  0o to 5o C.

4. 

Press the Enter Pushbutton.

3.10.4  EFT START

The EFT (Elapsed Flight Time) can be set to begin counting at unit turn on or at a prespecified altitude 

after take off.  The altitude after take off is the differential altitude from where the aircraft was tuned on 

as sensed by the internal encoder.  

1. 

Rotate the Data knob to select the EFT Start Alt page.

2. 

Press the Enter pushbutton.  The brackets will extinguish and the data will blink.

3. 

Rotate the Data knob to select the differential  altitude at which you wish the EFT timer to begin 

counting.  Note that if you select 0 feet, the EFT will begin counting at unit turn on.

4. 

Press the Enter pushbutton to select the EFT Altitude.

3.10.5  AUTO MODE C ALT

The STX 165 can be set to automatically select Mode C either at turn on or at a pre specified altitude 

after take off.  The altitude after take off is the differential altitude from where the aircraft was tuned 

on as sensed by the internal encoder.  This function can also be turned off, in which case it will turn on 
and stay in the SBY Mode until the pilot selects an alternative mode.

1. 

Rotate the Data knob until the Auto Mode C Alt page is selected.

2. 

Press the Enter pushbutton.  The brackets will extinguish and the data will blink.

3. 

Rotate the Data knob to select the differential altitude at which you wish the Mode C to be auto

-

matically selected.  Note that if you select 0 feet, Mode C will be selected at unit turn on.

4. 

Press the Enter pushbutton to select the EFT Altitude.

3.10.6  MIN BRIGHTNESS

The STX 165 uses a photo cell to sense the ambient light conditions and automatically adjust the 
brightness of the display.  This page allow the pilot to set the minimum brightness of the display to 
match other panel displays or his preference.  Note that the maximum brightness is preset at the factory 
and not adjustable.

1.  Rotate the Data knob to display the MIN Brightness page.

2.  Press the Enter pushbutton.  The brackets will extinguish and the display will show the level of 

the minimum brightness selected.

3.  Rotate the Data knob clockwise to increase the minimum brightness and counter clockwise to 

decrease the minimum brightness to the desired level.

4. 

Press the Enter pushbutton.

20

306100-00

Summary of Contents for STX 165

Page 1: ...STX 165 STX 165R Installation Manual 3700 Osuna Rd NE Suite 711 Albuquerque NM 87109 www sandia aero 306100 00...

Page 2: ...ce s continued product and quality improvement programs information contained in this document is subject to change without prior notice Copyright 2010 SANDIA aerospace Corporation All right rights re...

Page 3: ...Form STX 165 6 Environmental Qualifaction Form STX 165 R 7 Section 2 Installation Considerations 8 2 1 General 8 2 2 Mounting Considerations 8 2 2 1 STX 165 Panel Mount 8 2 2 1 1 Optional 3 Adapter P...

Page 4: ...mperature Unit 20 3 10 3 Icing Alert Temp 20 3 10 4 EFT Start 20 3 10 5 Auto Mode C Alt 20 3 10 6 Min Brightness 20 3 10 7 Default VFR Code 21 3 10 8 Exit User Set Up Mode 21 3 11 Continued Airwortine...

Page 5: ...ems that require altitude data A SANDIA aerospace STP 78 OAT probe P N 305561 91 can be installed as an option When the STP 78 is installed the STX 165 will display OAT Out side Air Temperature Densit...

Page 6: ...al TSO C88a C106 Operating Temp 55 o C 70 o C Altitude 35 000 1 3 4 Certification TSO C74d transponder C88b encoder STX 165 panel mount only Software DO 178B Level C Environmental DO 160F STX 165 A4C4...

Page 7: ...ry B Aircraft Type 5 Random Orientation Vibration 8 0 Tested to Category S Aircraft Zone 2 Vib curve M Explosion 9 0 Equipment Identified as Category X No Test Performed Waterproofness 10 0 Equipment...

Page 8: ...ry B Aircraft Type 5 Random Orientation Vibration 8 0 Tested to Category S Aircraft Zone 2 Vib curve M Explosion 9 0 Equipment Identified as Category X No Test Performed Waterproofness 10 0 Equipment...

Page 9: ...m Gray code format 2 2 MOUNTING CONSIDERATIONS 2 2 1 STX 165 Panel Mount The STX 165 is designed to be rear mounted in a 1 2 3ATI cutout The ATI Airline Transport Indi cator form factor is used in mos...

Page 10: ...AILURE TO DO SO COULD CAUSE DAMAGE TO THE TRANSMITTER 3 2 2 STX 165R Remote Mount 3 2 2 1 Supplied STX 165R P N 305831 00 Installation Kit 305994 00 9 Pin Sub D Female Connector P N 305214 Clamp D Con...

Page 11: ...l for the unit connectors and harness A panel punch is available from the factory for a nominal charge Contact the factory at 505 341 2930 Figure 3 1 Panel Cut Out Dimensions 3 3 Electrical The STX 16...

Page 12: ...tray it needs to be secured with two number 8 pan head mounting screws Ensure that the top of the screw head is below the mounting tray surface The STX 165R can be installed in either direction in th...

Page 13: ...r four mounting screws are required When mounting the unit ensure that enough clearance is allowed for the mating connectors 12 3 5 Static Port Connection The STX 165 has a built in altitude encoder t...

Page 14: ...t ALT XXXX CR The data formats are described in Appendix 1 For a yoke mount ident switch an external ident input is provided Grounding the External Ident line will activate the ident mode 3 6 2 STX 16...

Page 15: ...roximately 23 inches in length The installer can cut this cable to length or extend it by adding additional wire Make sure that any connections are away from areas that can accumulate water or chemica...

Page 16: ...y onto contact The cable may have to be held in a clamping fixture Arrange braid uniformly around crimp stem Slide crimp sleeve forward and crimp using recommended crimp tool Slide heat shrink froward...

Page 17: ...nd OAT Drain Grey Code 8 Aircraft Power Out Non Switchable 9 Altitude B2 Out 10 Altitude B4 Out 11 Altitude C1 Out 12 Altitude C4 Out 13 Altitude C2 Out 14 OAT Power Out OAT Probe Power Red Wire 15 OA...

Page 18: ...3 Altitude A2 In 4 Altitude A4 In 5 Altitude B1 In 6 Baud Select In 5v on Pin Changes J3 Pin 8 to 1200 Baud 7 Signal Ground Grey Code 8 Aircraft Power Out Non Switchable 1 Amp Max 9 Altitude B2 In 10...

Page 19: ...l be blinking Adjust the Data knob until the PALT display in the lower right hand corner of the display shows 35 000 feet 30 feet and press the Enter pushbutton Note that the altitude display is an un...

Page 20: ...ing on a battery the operator may wish this setting to be lower than the maximum of 1200 in order to conserve battery power 1 Rotate the Data knob to select the MAX REPLY RATE page 2 Press the Enter p...

Page 21: ...t unit turn on 4 Press the Enter pushbutton to select the EFT Altitude 3 10 5 AUTO MODE C ALT The STX 165 can be set to automatically select Mode C either at turn on or at a pre specified altitude aft...

Page 22: ...used in his local area 1 Rotate the Data knob to select DEFAULT VFR 2 Press the Enter pushbutton The brackets will extinguish and the first digit in the squawk code will blink indicating it is ready...

Page 23: ......

Reviews: