A
A
B
B
C
C
D
D
E
E
4
4
3
3
2
2
1
1
2. IN A DUAL DME CONFIGURATION THE SN3308 CAN ONLY DETECT DME
HOLD. IT ALWAYS ASSOCIATES DME-1 WITH NAV-1 AND DME-2 WITH
NAV-2.
SINGLE KING SERIAL DIGITAL DME USING KDI572
(ANY KING SERIAL DME PERMISSABLE)
3. THE SN3308 WILL NOT SUPPORT HOLD ANNUNCIATION ON ANALOG DME
USED AS DME-2.
4. THE SN3308 WILL SUPPORT REMOTE DISPLAY OF KN62/64 DME'S.
CONNECT AS SHOWN, TAKING "DME REQ" FROM REAR CONNECTOR PIN-N.
THE KN62/64 DO NOT HAVE A HOLD OUTPUT THEREFORE NO HOLD
ANNUNCIATION IS POSSIBLE.
NOTES:
B
COMMENTS
DME HOLD SHOWN TO KDI572. DME-1 NAV-2
SHOWN TO NAV-2.
DATE
FIRST RELEASE
7/10/98
A
REV
6/9/98
PAGE COUNT.
C
9/10/98
12/11/98
E
PAGE COUNT
COMPUTER CONTROLLED DRAWING
DO NOT REVISE MANUALLY
5/26/99
F
TOTAL SHEETS CHANGED TO 21
KN 63
Data Buss
Clock Buss
DME Request
D
F
6
Data Buss
8
DME Request
SANDEL SN3308
Clock Buss
27
9
P3
DME Request 15
12
11
DME 1 Hold
10
NAV 2 Common 49
2
DME Hold
DME Hold
E
KDI 572
DME
P2
Clock Buss
Data Buss
RNAV Request
DME Common
Clock Buss
Data Buss
NAV 2
Data Buss
RNAV Request
Clock Buss
DME Common
3
DME 1 Nav 2
17
RNAV Request
NAV 1 Common
48
NAV 1
Data Buss
Clock Buss
Data Buss
8
DME Request
SANDEL SN3308
Clock Buss
27
9
P3
DME Common
P2
RNAV Request
DME Common
Clock Buss
Data Buss
NAV 2
Data Buss
RNAV Request
Clock Buss
DME Common
3
DME 1 Nav 2
NAV 1
C
L
14
13
RNAV Request
DME Request
N
DME
1 or 2
Nav 2
Nav 1
10/23/00
G
ADDED KN 64 DME . ADDED NOTE 5.
DME REQ
27
NOTE 2
9
10
8
DATA
DME
HOLD
DME1
P2
DME1 HOLD
SANDEL SN3308
CLK
P3
DUAL KING SERIAL DIGITAL DME'S.
CLK
DME REQ
DATA
DME REQ
7
NOTE 2
26
3
25
DATA
DME
HOLD
DME2
P2
DME1 HOLD
CLK
CLK
DATA
SINGLE KING SERIAL DIGITAL DME WITH SELF CONTAINED CONTROLLER
(KN64 SHOWN FOR REFERENCE, KN62/KN62A PERMISSABLE)
KN 64 DME
MAINTENANCE PAGE SETUP FOR KING SERIAL DME
DME 1/2 CHANGE
DME1: KING DIGITAL
DME2: NONE
DME-1 HOLD ACTIVE LOW
DME-2 HOLD ACTIVE LOW
DME-2 HOLD DME 1 NAV2
5.
1. IN A SINGLE DME CONFIGURATION THE SN3308 DETECTS BOTH DME
HOLD AND NAV-1/NAV-2 ASSIGNMENT. WHEN NAV-2 IS CHANNELED THE
DME READOUT WILL ASSOCIATE WITH THE BEARING POINTER NAV-2
SELECTION. IF THE DME IS NOT ASSIGNABLE LEAVE THE CORRESPONDING
PIN UNCONNECTED.
(NOTE 4 & 5)
(NOTE 5)
P3
ADDED NAV1 & NAV2. TOTAL SHEETS CHANGED
TO 29.
(NOTE 1)
(NOTE 1)
04/03/01 G1
A/R 360 KN 63 DME NAV1 & NAV 2 WERE CONN
TO SN3308 P3-27 & P3-8. PAGE COUNT
G2
9/25/03
A/R 573 PAGE COUNT
DME REQ
ANALOG DME AS ONLY DME
ANALOG DME AS SECOND DME
DME1 HOLD
10
DME
HOLD
RELAY
DME ANALOG VALID
5
DME ANALOG -
P1
23
3
SANDEL SN3308
40MV/MILE
DME
P2
ANALOG DME
SIGNAL COM
VALID
P1
DME
DME ANALOG VALID
3
P2
SANDEL SN3308
5
23
ANALOG DME
DME ANALOG -
40MV/MILE
SIGNAL COM
VALID
NOTE 3
9
8
24
12
KDM706
G4
A/R661: Pinout for KDM706 added. Note on
permissibility added
10/04/02
Sunday, May 03, 1998
90106-10
G4
DME: KING SERIAL AND ANALOG
SANDEL
Vista, Ca.
B
17
29
SN3308 INSTALLATION DRAWING
Friday, September 26, 2003
Title
Size
Document Number
Rev
Create:
Sheet of
Category
Mod: