2
MONOBLOC FILTER INSTRUCTIONS
ENGLISH
SAFETY INSTRUCTIONS. READ CAREFULLY
•
All electrical installations should comply with the following standard;
NF C15-100
NF EN 60-335-2-41
that refers “to the construction of electrical installations, both in indoor and outdoor swimming pools”, or the equivalent
standard in force in each region or country.
•
All filtering should follow the C 15-100 installation standard that stipulates that all electrical apparatus located at less
than 3.5 m. from the pool and freely accessible, should be supplied by a very low voltage of 12 V. All apparatus
supplied with 220 V should be located at least 3.5 m. from the swimming pool edge. Ask the manufacturer for
permission to make any modifications in one or more elements of the filtering system.
•
The electrical installation should be performed by professional staff qualified in electrical installations.
•
The height of the sand should not exceed 2/3 of the height of the tank.
•
The apparatus must not be on while the pool is being used.
•
Do not operate the apparatus unless it is properly primed.
•
NEVER touch the filter when it is operating if you are wet or have wet hands.
•
When handling the filter or valve, DISCONNECT the power supply.
•
Make sure that the ground is dry before touching the electrical equipment.
•
Do not install the filter where it could become wet, as it may cause electrocution.
•
Do not allow children or adults to lean against or sit on the apparatus.
•
If the supply flex of the apparatus is damaged, it should be replaced. Read the instructions carefully to replace it.
If in doubt, contact the technical service.
1 PACKAGING COMPONENTS
The filter which you have just purchased is a device which is especially planned and designed for elevated pools. As a
result of its innovative design and high level of functionality, it provides you with the different components required to filter
water: filter, pump and selector valve in a single unit. The main components of this filter are as follows:
Modelo
Fig.
Pos.
Denominacion
AR700 / AR700C
1
1
TOP selector valve
AR700 / AR700C
1
2
Filter Ø300
AR700 / AR700C
1
3
Plastic Base Ø300
AR700 / AR700C
1
4
Hose connection of Ø38 x 360
AR700 / AR700C
1
5
Protective housing
AR705 / AR705C
1
1
TOP selector valve
AR705 / AR705C
1
2
Filter Ø300
AR705 / AR705C
1
3
Plastic Base Ø300
AR705 / AR705C
1
4
Hose connection of Ø38 x 360
AR705 / AR705C
1
6
Pump 0,4cv
AR705 / AR705C
13
1
Pipe cup
AR705 / AR705C
13
2
Nut Ø 2 1/4"
AR705 / AR705C
13
3
Discharge sleeve Ø38
AR705 / AR705C
13
4
O-Ring
AR710 / AR710C
1
7
Plastic base Ø380
AR710 / AR710C
1
8
Filter Ø380
AR710 / AR710C
1
10
TOP selector valve
AR710 / AR710C
1
12
Hose connection of Ø38 x 580
AR710 / AR710C
1
13
Pump 0,6cv.
AR710 / AR710C
13
1
Pipe cup
AR710 / AR710C
13
2
Nut Ø 2 1/4"
AR710 / AR710C
13
3
Discharge sleeve Ø38
AR710 / AR710C
13
4
O-Ring