background image

2

3

Thank you for purchasing a San Jamar digital scale. Please read the  

following operation information to ensure the proper function of your new scale.

AC/DC ADAPTER (OPTIONAL)

1.  Plug the adapter jack into the socket.
2.  Plug the adapter to the AC main.

LEVEL THE SCALE
When the scale is put to use at a new location, adjust the level of the scale by  
turning the 4 level adjusting feet until the bubble is located in the middle position of 
the bubble leveler.

POWER OFF

1.  The scale can be powered off manually by pressing the 

ON/OFF key.

ACTIVATING THE SCALE

1.  Turn the scale on by pressing 

ON/OFF key.

2.   The LCD screen will show all characters for a few seconds, and then “0.000 ” 

will be shown on the display.

BACK LIGHT

1.   You can turn the 

BACK LIGHT on or off by pressing the BACK LIGHT key. 

PRODUCT SPECIFICATIONS
Model:
 SCDG33BK
Capacity: 33 lb / 15 kg
Graduation: 0.1 oz / 1 g
Platform Dimensions: 8” x 6.25”
Product Dimensions: 8.25” x 8.5” x 3.75”
Power Source: 4 - C Batteries
Automatic Shut-off: 2 minutes
NSF Certified

WEIGHING AN ITEM

1.  Turn on the scale.
2.  Place an item on the platform.
3.  The weight of the item will be displayed.

SELECTING WEIGHT UNIT

While the scale is on, press the 

UNITS

 button to move right-aligned arrow 

through unit options.

USING THE HOLD FUNCTION

While an item is on the platform, press the 

HOLD

 key once and then remove the 

item. The scale will continue to hold the original weight for 10 seconds.

USING THE TARE MODE

1.  Turn the scale on.
2.  Place an item on the weighing platform, weight value will display.
3.  Press the 

TARE key. The weight of the item will return to “0.000 .” 

4.  Place next item on the platform and note the reading.

NOTE:  The scale will display a negative reading when you remove all items. Press 
the 

TARE key once, and the negative reading will disappear. 

USING THE COUNTING MODE: SET SAMPLE SIZE

1.  Turn on the scale.
2.   Press and hold the 

PCS key for about 3 seconds until a flashing number  

is displayed.

3.   Press  the 

MODE key to select the sample size in the sequence of 10 

 20 

 

40 

 60 

 80 

 100

4.   Once you have determined your desired sample size; place the samples on  

the platform. (Example: For a sample size of 10, place quantity of 10 onto the 
platform, for sample size of 20, place quantity of 20, etc.)

5.   Press  the 

PCS key to confirm the sample size. You can now add, and  

subtract samples.

6.  Press the 

PCS key again to return to weighing mode.

In order to ensure accurate counting figure, the minimum unit sample weight must 
be > ld, and the counting size must not exceed 65535 pcs. If over 65535 pcs, the 
LCD will display “- - - -”