background image

 

 

 

21 

 

4.3.22. 

To 

make 

intermittant 

transmittion  for  suppressing  electric 
power of Radar. 

ATTENTION 

 Pay consideration to the surrounding condition 

as there is high potentiality in collision with a 

fast  moving  dangerous  thing  or  vessels  when 
the  Radar  is  on  Stand-by  at  intermittant 
transmitting set. 

a)

 

‘TIMED  TX’

  consisits  of 

‘TX  PERIOD’

  / 

‘STAND-BY TIME’

b) 

In case of setting

 ‘TX  PERIOD

’ for

  10-SCAN, 

‘STAND-BY TIME’ 

for

 3-min, ‘TIMED TX’ 

for

 On, 

  After  the  scanner  rotate  10  times,  the  screen  is 

changed  to 

ST-By  and  it  is  counted  after

  3 

minutes  later,  returned  to  PPI  screen.  In  a  ST-By 
screen, the scanner (air cable) / monitor is stopped. 

 

(1) Transmit interval set-up 

  Transmit  unterval  is  set  by  the  revolution  of 

Antenna. 

                   Menu screen 

             Move to 

RADAR SET-UP

 

   Move to 

TX PERIOD

, press

 

  

10-SCAN, 20-SCAN, 30-SCAN 

(Move / select for desirable values)

 

                   Back to PPI screen 

 
(2) Stand-by interval set 

 Stand-by time is set by 3, 5, 10, 15 min. 

                   Menu screen 

             Move to 

RADAR SET-UP  

   Move to 

STAND-BY TIME

,   

press

 

  

3-min, 5-min, 10-min, 15-min 

(Move / select for desirable values)

 

                   Back to PPI screen 

 

(3) Intermittent transmit 

                   Menu screen 

             Move to 

RADAR SET-UP

 

   Move to 

TIMED TX

, press

 

 

On  : 

According  to

  ‘TX  PERIOD’  /

 

‘STAND-BY 

TIME’ 

values, 

the 

intermittent transmit is started.

 

Off : 

End.

 

                   Back to PPI screen 

 

4.3.23.  To  display  ECHO  image  long 
on PPI screen. 

CAUTION 

  When  designating  the  target 

magnification  and  wider  tranmit  pulse 

width,  the  images  over  two  targets 
accessed  from  fore  and  after  direction 

and  angle  direction  can  be  dispayed  in 
one image on screen. 

  Use  the  following  functions  to  display  ECHO 

image large. 

a) Use the function of target magnification. 
b) Set Tx pulse width long. 

(1) The Target Magnification Function 

                   Menu screen 

             Move to 

RADAR SET-UP

 

   Move to 

TARGET MAG.

, press

 

   

On

  :  The  target  size  displayed  on 

Screen is magnified twice. 

Off 

: It returns to the first screen.

 

                   Back to PPI screen 

 
(2) TX Pulse Width Change Function 

 Defaulting Set is 

‘Short’

 and if you select, 

‘Long’,

 

the target on the screen is displayed Long. 

                   Menu screen 

             Move to 

RADAR SET-UP

 

   Move to 

TX PULSE

, press

 

 

Long 

:  TX  PULSE  width  can  be 

changed at 1.5, 3, 6 mile. 

Short 

: It returns to the first screen.

 

                   Back to PPI screen 

 

4.3.24.  To  change  the  color  of  PPI 
screen and ECHO image 

(1) Set the color of ECHO image 

                   Menu screen 

             Move to 

INIT. SET

 

   Move to 

COLOR SET

, press

 

 

green/yellow/rad/white/color 

(Select  desirable  colors  to  show  a 

display  to  adjust  color  levels  in  a 

screen.)

 

                   Back to PPI screen 

 

Summary of Contents for SMR-3700

Page 1: ...How to operate the unit 13 4 1 General Idea 13 4 1 1 Power Input and Operation 13 4 1 2 Tuning Control 13 4 1 3 Image Control 13 4 1 4 Power Off 13 4 2 Stand by for Processing 13 4 2 1 Brightness Cha...

Page 2: ...ter 6 Installation 25 6 1 Overview 25 6 2 Installation of Antenna 25 6 2 1 Selection of the installation place 25 6 2 2 How to install Antenna 25 6 2 3 Connection to Equipment cable 26 6 3 DISPLAY SET...

Page 3: ...play Unit SMR 3700 monitor is designed to receive the input signal from Scanner and displays the optimum conditions on the TFT LCD screen based on the SAMYUNG s best digital signaling technology 1 10...

Page 4: ...ed 51 5m sec 100 knots 11 Power Consumption 60W 12 DC Power DC 10V 36V 13 Preheating Time 90 Secs 14 Preaction Within 3 Secs 1 5 2 Scanner RSU 3700 1 Dimentions a Diameter 590mm b Height 290mm 2 Weigh...

Page 5: ...ont Panel a Tune Knob b Gain Knob c Rain Snow Removal Knob d Sea Cluter Removal Knob e Guard Switch f Distance Circle Switch g Interference Rejection Switch h Heading Line Switch i Parallel Line Switc...

Page 6: ...ing it needs to be measured only straightline from obstacle which should be 1 2 time This radar is calculated automatically 2 4 Measurement of a Course One way to measure the distance to an object is...

Page 7: ...the set value or select the menu item To dark LCD display brightness Stand By and TX conversion To call Menu display Directional button To light LCD display brightness To turn ON OFF To remove any in...

Page 8: ...d Setup 5 Parallel Line 6 Heading Line 7 1 EBL 8 Cursor Position Bearing Distance Arrival Time 9 Display Color 10 Indication of the set EBL VRM bearing distance 11 1 EBL VRM 12 2 EBL VRM 13 F EBL VRM...

Page 9: ...ctions to enable user to control with menu 3 3 1 Menu Composition It is available to converse the display language to Korean English Russian Chiness For the conversion of the display language please r...

Page 10: ...ial Setup Menu for installer At INIT SET of MENU press button the following display will appear For any additional item please refer to 6 6 Initial Setup by Installer Initial Setup by Installer Additi...

Page 11: ...cording to the time intervals Short 5 Circles Long 10 Circles WAYPONT To display the position of the target on the screen HEADING MODE To select the display of the own ship heading RADAR SET UP TIMED...

Page 12: ...top color of the screen INSIDE COLOR To set up the internal desktop color of the screen COLOR SET To set up PPI image color Initial Setup by Installer DISPLAY TIMING To adjust the PPI image distance T...

Page 13: ...st the image biggest b Adjust the movement of the tuning bar biggest c In case of the automatic tuning mode it is needless to turn the volume d If any image doesn t appear adjust the volume again or t...

Page 14: ...emove the echo image by snow and rain Reflected Wave of Rain Snow Removed Rain Snow Target Retricted too ATTENTION It should be always observed by adjusting the optimum conditions If the gain is too l...

Page 15: ...tion a How to set up Alert Zone based on the position of own ship as selecting Ring function The message of Press ENT to set is shown onto a screen with a red ring mark Adjust the Alert Zone controlli...

Page 16: ...ed in 3 steps 4 3 9 To remove the Radar Interference ATTENTION When using the function of Intereference Removal weak image such as a dangerous thing may happen to be removed Stop the function of inter...

Page 17: ...Able to adjust EBL Able to adjust VRM Function is end 2 Press button The method of adjustment is same as 1 EBL VRM 3 How to measure bearing distance from a target to target by using F EBL VRM function...

Page 18: ...ess Back to PPI screen 1 HEAD UP a Ship s head is displayed to the HEAD UP Its bearing scale is 0 on PPI screen b If ship s head is changed ECHO image bearing on screen is also changed c If you could...

Page 19: ...Bearing a True bearing indication is set based on True North with Scale 0 b It requires the equipment like GYRO COMPASS to obtain bearing reference 2 Magnetic Bearing a Magnetic Bearing indication is...

Page 20: ...4 3 20 To display the Waypoint To use this function it needs the input of bearing data distance data to go waypoint and own ship s speed data on the indicator Menu screen Move to FUNC DISPLAY SET Mov...

Page 21: ...SET UP Move to TIMED TX press On According to TX PERIOD STAND BY TIME values the intermittent transmit is started Off End Back to PPI screen 4 3 23 To display ECHO image long on PPI screen CAUTION Whe...

Page 22: ...reen 4 4 Other convenient function 4 4 1 Display own ship s speed on the indicator a To use this function own ship s speed data is needed to the indicator b The own ship s speed data is shown at a cen...

Page 23: ...these are of theoretical value and would not be constant due to environmental condition In theory the target 10 miles away from the antenna requires 7 6 meters height if it is lower than 7 6 meter EC...

Page 24: ...the direction in order to observe the targets with care 2 Side echo There may be an image of arc wave line in the same distance from target image on the screen This is caused by the side lobe of whic...

Page 25: ...t is apt to be sliding in slant toward the counter windy side while the yaucht is navigating when the wind is blowing to the extent In case the slanted angle being over 1 2 of beam width the electric...

Page 26: ...nal Connected Display TX RX Motor ANT Bearing sensor 1 2 3 4 ATTENTION Fix the cable with tie Don t bend the connector too much when input the cable into the Radome for preventing from the damage Hexa...

Page 27: ...nts are the cable connection tight connection of each units aireal cable the connection of cable shield 6 5 Operation check 1 Before the operation check it needs to check if the internal voltage is in...

Page 28: ...PPI screen comes up and displayed number in the middle of top screen The distance range is auto changed to 6NM Adjust it to make a target of PPI screen maximum size Ref Adjust Range 000 255 1 Step Ad...

Page 29: ...is adjusted to 7 8 steps Ref Adjust Range 000 255 1 Step Adjust 10 Step Adjust Rotate the controller from a center to the left right and make the bar of the Tune indicator to max in a middle of point...

Page 30: ...is set as a display of heading nearby 0 5 1 5NM and adjust to locate the target on a heading line of the PPI screen Ref Adjust Range 90 0 90 0 0 1 Step Adjust 1 0 Step Adjust In case of increasing the...

Page 31: ...ditional menu out of default settion menu Move to DISPLAY TIMING Select PPI screen comes up and displayed number in the middle of top screen Adjust the target of waypoint to reach at the real distance...

Page 32: ...er another It is displayed additional menu out of default settion menu Move to GAIN L SET Select PPI screen comes up and displayed number in the middle of top screen Ref Adjust Range 000 255 1 Step Ad...

Page 33: ...es up and displayed number in the middle of top screen Adjust to disapper noise to 6NM Adjust to have little noise in a ring of 6NM Ref Adjust Range 000 255 1 Step Adjust 10 Step Adjust If the values...

Page 34: ...itional menu out of default settion menu Move to MBS SET Select PPI screen comes up and displayed number in the middle of top screen Suppress the signal of Main Bang to the desirable distance Ref Adju...

Page 35: ...ower on monitor because it is still excited even Radar stopped 7 2 Scanner When maintained a wireline cut off the power of monitor and then protect the power supplied into the wireline Don t place wat...

Page 36: ...acket 1 CODE NO ACC RADAR 001 3 Knob 6 20 2 CODE NO ACC 6X18MM 002 4 Scanner RSU 3700 1 CODE NO RSU 3700 5 Scanner Cable SAMYUNG 11 X 16C 1 Cap SRCN2A25 16P L 15m CODE NO RSU 3700 15M 6 Power Cable CV...

Page 37: ...001 9 10 11 12clause packings 9 6Angle Bolt 10 X 25 4 CODE NO ACC SC 001 10 Spring Washer 10 4 CODE NO ACC WA 001 11 Plain Washer 10 4 CODE NO ACC WA 002 12 Bottom Pad 50 4 CODE NO ACC PAD 001 13 Fus...

Page 38: ...38 Chapter 9 Installation drawing and circuit diagram...

Reviews: