TEMPERATURE LIMIT SETTINGS
BM Shutdown Temp – High Temperature Limit at which the unit will shut
off
. The
factory default is 415 degrees F. The adjustable range is from highest minimum
thermocouple temperature to lowest maximum thermocouple temperature, typically 0-
777 degrees F.
BM SP MIN/MAX – The minimum/maximum Before-Mix air temperature set point (SP)
the user can adjust the control to is set in this step. The factory default is 350 degrees F.
The adjustable range is from highest minimum thermocouple temperature to lowest
maximum thermocouple temperature, typically 0-777 degrees F.
AM SP MIN/MAX – The minimum/maximum After-Mix air temperature set point (SP)
the user can adjust the control to is set in this step. The factory default is 100 degrees F.
The adjustable range is from highest minimum thermocouple temperature to lowest
maximum thermocouple temperature, typically 0-777 degrees F.