Engl
ish
English
19
Ducting requirements
Weather hood type
Recommended
Use only for short-run
installation
4” (10.2 cm)
2.5” (6.4 cm)
No. of 90° elbows
Rigid
Rigid
0
80 ft. (24.4 m)
74 ft. (22.6 m)
1
68 ft. (20.7 m)
62 ft. (18.9 m)
2
57 ft. (17.4 m)
51 ft. (15.5 m)
3
47 ft. (14.3 m)
41 ft. (12.5 m)
NOTE
* Use a 4-inch (10.2 cm) diameter rigid aluminum or galvanized steel duct.
If you integrate the dryer’s vent system with an existing exhaust system:
• Make sure the exhaust system meets all applicable local, state, and national regulations.
• Verify you are not using flexible plastic duct.
• Make sure to check for and remove all lint buildup from inside the existing ducts.
• Confirm the duct is not kinked or crushed.
• Make sure the exhaust hood damper opens and closes freely.
Manometer measurements
The static pressure in any exhaust system must not exceed 0.83 inches of water column or be less than 0.
Note that these values are measured with the dryer running with a manometer presented to the exhaust
duct that connects to the dryer. The dryer tumbler must be empty and lint filter clean.
Untitled-6 19
2022-03-30 12:14:20
Summary of Contents for WF46BG65 A Series
Page 1: ...Washer Usermanual WF46BG65 A WF53BB89 A Untitled 1 1 2022 05 26 6 39 31...
Page 77: ...Lave linge Manueld utilisation WF46BG65 A WF53BB89 A Untitled 2 1 2022 05 27 10 21 09...
Page 157: ...M mo Untitled 2 81 2022 05 27 10 21 23...
Page 158: ...M mo Untitled 2 82 2022 05 27 10 21 24...
Page 159: ...M mo Untitled 2 83 2022 05 27 10 21 24...
Page 161: ...Lavadora Manualdelusuario WF46BG65 A WF53BB89 A Untitled 4 1 2022 05 26 6 53 01...