17
TROUBLE DIAGNOSIS
Wet Clothes
• Unbalance due to not enough load. Put additional load.
• Due to excessive suds by using general detergent. Use HE (High-Efficiency) or reduce its quantity.
• Low Spin Speed or Drain Only was selected.
• Go to “ Will Not Spin”.
Will Not Lock
• Door is not aligned or closed properly.
• Perform Quick Test Mode. Check Door Lock.
Check the output voltage of Door Lock Coil.
If it reads 120V, change Door Lock Switch, and if not, change PCB. (Refer to PCB Connector Check.)
• Read Lock Switch and PCB (CN3). (Refer to PCB Connector Check.)
• Try Door Lock and check for 120V to Door Lock Connector. If 120V present, change Main Control Board and
if not, change Door Lock switch.
Will Not Unlock
• Check if the door is being pushed out, which may keep it from unlocking.
• Door locks itself when the water level is too high. Opening door will result in water draining from door
opening.
• Check the following with Board Input Test Mode.
Water Level (frequency): Over 23.80 KHz.
If so, refer to “Will Not Drain”.
Temperature (Inside Drum): Higher than 60ºC/140ºF.
If so, wait until it drops.
When everything is normal, check PCB connectors and Door Lock Switch.
• Drain manually after removing the plastic drain hose holder.
• Display shows “LO”. Turn off and on the unit. If “LO” keeps illuminating, check PCB and Door Lock Switch.
TROUBLE SHOOTING
To avoid risk of electrical shock, personal injury or death; disconnect power to washer
before servicing, unless testing requires power.
WARNING
Techsheet-WF350AN-02834A-03_EN.indd 17
2011-09-28 �� 4:00:32
Summary of Contents for WF331ANW/XAA
Page 23: ...MEMO Techsheet WF350AN 02834A 03_EN indd 23 2011 09 28 4 00 33 ...
Page 24: ...Techsheet WF350AN 02834A 03_EN indd 24 2011 09 28 4 00 33 ...
Page 47: ...MÉMO Techsheet WF350AN 02834A 03_CFR indd 23 2011 09 28 3 52 30 ...
Page 48: ...Techsheet WF350AN 02834A 03_CFR indd 24 2011 09 28 3 52 30 ...