CHAPTER 2. Basic System Configuration
© SAMSUNG Electronics Co., Ltd.
page 43 of 689
2.1.3
APC Management Port Configuration
To connect to the APC remotely using telnet/SSH or web, it is necessary to set up an IP
address to the management port.
Set up the management port as follows:
1) Go to configure
‘mgmt0’ interface configuration mode of CLI.
WEC8500# configure terminal
WEC8500/configure# interface mgmt0
2) Set up an IP address.
WEC8500/configure/interface mgmt0# ip address 100.100.100.1/24
In case of WEC8050, there is no management (mgmt0) port. After establishing an
IP address in one of ports ge1 to ge4 by referring to the contents of 'Port
Configuration' and then using the CLI, connect the Ethernet cable to the port.
2.1.4
SNMP Community Configuration
To connect to the web server of APC, it is necessary to add Simple Network Management
Protocol (SNMP) community through CLI. For more information, see ‘10.1 SNMP
Configuration’.
2.1.5
CLI Basic Usage
The CLI is a text command based interface used to change or retrieve the system settings.
Several users can change the settings at the same time using the CLI of the same system.
Because privilege per user is already configured, a user can execute a command allowed by
the user’s privilege. Various commands are available for each system function. For more
information, see ANNEX ‘CLI Command Structure’.
Command Help
The CLI provides a help for all the commands. To see a help for a command and parameter,
enter ‘?’. Based on an input character, it shows a help for a command or parameter that can
be entered.
Category
Description
?
Displays the command list and help at the current level
Command ?
Displays the parameter and help required for a command