7
3.SPIN FUNCTION
(1) The Spin function allows the Washing Motor to rotate to the left and to maintain the Drain Valve
opened for the whole spinning time.
(2) Other functions are as identical as Intermittent Spin function.
(3) Spin time for rinse course is 2 min. and 30 sec. for wool course.
(4) Spin time for spin course performs its working during the selected time.4.PAUSE FUNCTION
4.PAUSE FUNCTION
(1) The Pause function turns ML OFF for 1 min. and 30 seconds and turns the Drain Valve ON continuously.
(2) If the Door is opened while the Pause function is in operation during the Rinse cycle, it gives Door Open
Error and resumes processing after Door is closed.
(3) If the door is opened while the Pause function is in operation during the Spin cycle, it exits the Spin function.
5.WATER SUPPLY FUNCTION
(1) Identical as the Water Supply function of Wash process
6.RINSE FUNCTION
(1) If a selected water level is fulfilled, the Rinse function is performed.
(2) Rinse time is 2 min 30 sec performal regradless of time. (2 min. for wool course, 1 min. 30 sec. for econo course)
2-3-3 SPIN PROCESS
(1) Identical as the Intermittent Spin and Spin functions of Rinse process
(2) Spin function for 1 min. performs as identical as wool course.
2-3-4 EXIT PROCESS
(1) After all the selected process is completed, it performs Exit process.
(2) While the exit function is in operation it gives End melody and turns off all the driving compartment.
The display shows "DISPLAY END
”
(3) If the Exit function is finished, it automatically turns Power Relay OFF.
2-4 SPECIAL FUNCTIONS
2-4-1 ERROR FUNCTION
1.WATER LEVEL SENSOR ERROR
(1) When the Water Level Sensor detects a frequency less than 15KHz or more than 30KHz for more than 5 seconds
(2) Generates ERROR MELODY 5 times.
(3) DISPLAY : '1E'
(4) How to Clear : Press the start to check again.
2.WATER SUPPLY ERROR
(1) When the Water Supply does not reach for the selected water level after 60 min has passed since
starting to supply water.
(2) Generates ERROR MELODY 5 times.
(3) Display "E" 0.5 sec ON/OFF
(4) How to Clear : Press Start Key to clear the Error status and to resume Water Supply.