Outdoor unit installation
E-
9
ENGLISH
Fix the outdoor unit with anchor bolts.
◆
The anchor bolt must be 20mm or higher from the base surface.
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
Type C
660
880
310
340
364
Anchor bolt hole
Type B
Type A
660
880
310
340
364
543
790
280
319
340
Anchor bolt hole
Anchor bolt hole
Unit : mm
The outdoor unit must be installed on a rigid and stable base to avoid any increase in the
noise level and vibration, particularly if the outdoor unit is to be installed in a location
exposed to strong winds or at a height, the unit must be fixed to an appropriate
support(wall or ground).
◆
Make a drain outlet around the base for outdoor unit
drainage.
◆
If the outdoor unit is installed on the roof, you have to check
the ceiling strength and waterproof the unit.
C
C
C
C
A
A
A
A
U
U
U
U
T
T
T
T
II
II
O
O
O
O
N
N
N
N
20mm
Anchor bolt
Outdoor Unit
➔
Outdoor Unit Support
Base Surface
➔
UH026EAV IM_E_24005 12/29/05 10:56 AM Page 9