3-4
Samsung Electronics
Alignment and Adjustments
3-1-2 Wired Remocon Error Display
Display
Explanation
Remark
Indoor unit Communication Error
Communication ERROR
Indoor/Outdoor unit Communication Time Out Error
60 Packet Over data
Indoor unit is not connected
Communication Error between Outdoor Main and Inverter Micom
(Occurred after 1 minute detection in Main and Inverter)
Indoor Temp. Sensor(OPEN/SHORT ERROR)
INDOOR SENSOR ERROR
Indoor Unit Eva in sensor(OPEN/SHORT ERROR)
Indoor Unit Eva in sensor Separation
Outdoor Temp. Sensor Error(OPEN/SHORT ERROR)
OUTDOOR SENSOR ERROR
COND Temp. Sensor Error(OPEN/SHORT ERROR)
Inverter Compressor Discharge Temp. sensor Error(OPEN/SHORT ERROR)
Indoor Float S/W 2
nd
Detection
SELF DIAGNOSYS ERROR
Outdoor unit-Indoor unit Communication wire Voltage Detection
Outdoor unit Refrigerant Full Leakage(Gas Leak)
Outdoor door Fan Error
[Inverter]Inverter Compressor Start Failure
OUTDOOR UNIT PROTECTION
CONTROL ERROR
[Inverter]DC PEAK Error
[Inverter]DC LINK Voltage 150V below, 410V Over
[Inverter]Compressor Rotation Error
[Inverter]Current Sensor Error
[Inverter]DC LINK Sensor Error
[Inverter]EEPROM READ/WRITE Error
[Inverter]Inverter ZERO CROSSING Error
Outdoor unit Capacity Setup Option Error
Wired Liquid Crystal
↔
Indoor unit Comm. Error
WIRED REMOTE CONTROL ERROR
Master Wired Liquid Crystal
↔
Slave Liquid Crystal Comm. Error
Wired Liquid Crystal COM1/COM2 Cross Error
Error of setting option for wired remote controller COM2
24867A(1)_TH026EAV_1.indd 4
2006-05-09 ソタネト 2:53:21
Summary of Contents for TH060EAV
Page 48: ...MEMO Samsung Electronics 4 26 ...
Page 59: ...Samsung Electronics 5 4 Ass y Control Out UH026EAV DB93 03453B UH035EAV DB93 03453A 5 11 ...
Page 145: ...13 6 Samsung Electronics OUTDOOR FAN B D DIODE IPM DC_LINK CAP SMPS IGBT Block Diagram ...
Page 156: ...MEMO Samsung Electronics 14 11 ...
Page 157: ...Samsung Electronics MEMO 14 12 ...