10-1
The red number connecter is not used.
10. PCB Diagram
10-1 Indoor PCB
Samsung Electronics
Ventilator : YW396-03AV(BLK)
Floating Switch : SMW250-02(BLK)
Drain Pump : YW396-03AV(WHT)
Room/Eva.-In Temp. Sensor : SMW250-04(WHT)
Indoor Fan(SSR Control) : YW396-05AV(WHT)
Eva.-Out Temp. Sensor : SMW250-02(WHT)
AC Power : YW396-03AV(BLU)
Heater Discharge Temp. Sensor : SMW250-02(YEL)
Indoor Address S/W(Main, RMC)
RPM Feedback : SMW250-03(BLU)
Option Switch
Communication2(Wired Remocon_F3/F4) : YW396-02V(BLU)
Electrical Expansion Valve(EEV) : B5B-XH-A(BLU)
Communication1(Outdoor_F1/F2) : YW396-02V(RED)
SUB-PCB Connection : SMW250-05(YEL)
DC12V Out(Wired Remocon Power) : YW396-02V(WHT)
Panel Louver(Stepping Motor) : SMW250-10(WHT)
Micom Program Download : SMW200-10(BLK)
External Control Out(Error, Compressor State) : SMW250-04(RED)
Display PCB : SMW200-9(WHT)
External Control In(On/Off Control Signal) : SMW250-02(RED)
SSR Fan Control : SMW250-03(WHT)
1
2
3
4
5
6
7
8
7
9
10
11
13
14
15
16
17
18
19
20
21
22
12
11
12
13
14
15
16
1
2
3
4
22
7
8
10
6
5
17
18
19
20
21
9
24867A(1)_TH026EAV_1.indd 1
2006-05-09 ソタネト 2:56:30
Summary of Contents for TH060EAV
Page 48: ...MEMO Samsung Electronics 4 26 ...
Page 59: ...Samsung Electronics 5 4 Ass y Control Out UH026EAV DB93 03453B UH035EAV DB93 03453A 5 11 ...
Page 145: ...13 6 Samsung Electronics OUTDOOR FAN B D DIODE IPM DC_LINK CAP SMPS IGBT Block Diagram ...
Page 156: ...MEMO Samsung Electronics 14 11 ...
Page 157: ...Samsung Electronics MEMO 14 12 ...