| 5
RADVISION | RADVISION Port Security Reference Guide
In addition to the ports listed in
Table 1-1
, the SCOPIA Elite MCU offers configurable security
access levels enabling and disabling Telnet, FTP, SNMP and ICMP (ping) services. The security
settings are accessed in the MCU from Configuration > Setup > Security and entering the
Security Mode.
Table 1-2
details the implications of each security mode on each communication
type.
1719
(configurable)
RAS (UDP)
RAS signaling
Out
Cannot communicate
with H.323 gatekeeper
H.323 gatekeeper
1720
(configurable)
Q.931 (TCP)
Q.931 signaling
Both
Cannot connect H.323
calls
Any H.323 entity
3336
XML (TCP)
MCU version 3 XML API Both
Cannot use MCU
Conference Control web
user interface. Cannot
use version 3 XML API to
control MCU
Conference Control web
client terminal, iVIEW
Management Suite or
third-party controlling
applications
3337
XML (TCP)
MCU version 3
Cascading XML API
Both
Cannot cascade
between two MCUs
Other MCUs
3338
XML (TCP)
Administration XML API Both
Cannot be blocked
5060
(configurable)
SIP
(TCP/UDP)
SIP signaling
Both
Cannot connect SIP calls Any SIP entities
Table 1-1
Ports Supported by SCOPIA Elite MCU 5000 Series
Port Range
Protocol
Functionality
Direction Result of Blocking Port
on Firewall
Description
Table 1-2
MCU Security Mode
Security Mode
Telnet
FTP
SNMP
ICMP (ping)
Standard
Active
Active
Active
Active
High
Inactive
Inactive
Active
Active
Maximum
Inactive
Inactive
Inactive
Inactive