4-2
4. Troubleshooting
4-2. When the Power Does Not Turn On
Symptom
- When turning on the Power button after connecting the power cable, the LED at the front of the
monitor does not operate.
Major checkpoints
- When turning on the Power button after connecting the power cable, the LED at the front of the
monitor does not operate.
- Check the IP board power fuse and the IP board output power.
- Check the connections for the IP board and the Main board inside the monitor.
- Check the Main board power part and also check whether there is any abnormal output at any of
the other output terminals.
Diagnostics
CN600
IC601
IC602
Yes
Check the connection status for
the function assy.
Yes
Replace the IP board.
No
Is DC 5V measured at pins 5, 6 of the
CN600 connector when pins 3, 4 are
0V?
IIs DC 3.3V measured at pin 3 of IC601
when pin 1 is DC 5V?
Check the circuits related to
IC601.
No
Yes
Check the circuits related to
IC602.
No
Is DC 1.8V measured at pin 2 of IC602
when pin 3 is DC 5V?
Yes
Check and replace the IP board.
Caution
Make sure to disconnect the power before working on the IP board.
Summary of Contents for SyncMaster EX2220
Page 5: ...3 2 3 Disassembly and Assembly Description Photo Screws 3 Turn the monitor over again ...
Page 17: ...1 4 1 Precautions Memo ...
Page 21: ...2 4 2 Product specifications Memo ...
Page 24: ...4 3 4 Troubleshooting 4 2 1 Circuit diagrams when the power does not turn on ...
Page 26: ...4 5 4 Troubleshooting 4 3 1 When a blank screen is displayed Analog ...
Page 27: ...4 6 4 Troubleshooting 4 3 2 Waveforms when no screen is displayed Analog ...
Page 29: ...4 8 4 Troubleshooting 4 4 1 Circuit diagrams when a blank screen is displayed Digital ...
Page 30: ...4 9 4 Troubleshooting 4 4 2 Waveforms when a blank screen is displayed Digital ...
Page 40: ...6 1 6 Wiring Diagram 6 Wiring Diagram 6 1 Wiring Diagram Main Board ...
Page 41: ...6 2 6 Wiring Diagram 6 2 Wiring Diagram IP Board ...
Page 43: ...6 4 6 Wiring Diagram Memo ...