QUICK GUIDE
English_
11
ENG
Item
Cable Color
Power Supply
Unit
Connect the DC+12V to the red line.
Connect GND to the black line.
Wiegand
Connection
Connect the green line of the product to the Wiegand D0 input port of the controller.
Connect the white line of the product to the Wiegand D1 input port of the controller.
LED Control
To control the LED indicators, connect the yellow line to the output port (relay) of the
controller.
Buzzer
Control
To control the built-in buzzer, connect the blue line to the output port (relay) of the
controller.
RS-232
Connection
Connect to the COM port of the PC. (Connect pin 2 of the DB-9 connector to the purple
line; connect the black line of the device (GND) to pin 5 of the DB-9 connector)