SPEED DOME CAMERA
User Guide
24
SPEED DOME CAMERA
User Guide
25
No.
Baud Rate(BPS)
SW2-#5
SW2-#6
1
2,400
ON
ON
2
4,800
ON
OFF
3
9,600
OFF
OFF
4
19,200
OFF
ON
Function
ON
OFF
SW2- #7
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
Function
ON
OFF
SW2- #8
Response Mode Switch
Response
No Response
Select the transfer speed of a selected communication protocol.
Select a communication method for the camera.
Select a communication response method for the camera and controller: Response or No
Response.
•
Baud Rate Settings
•
Communication Method Settings
•
Communication Response Settings
Camera Input Position
SW2- #10
SW2- #11
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
•
Termination Settings
Installing Your Camera
Installing Your Camera
ON
ON
OFF
SW2
Communication Protocol DIP Switch Settings (SW2)
•
Protocol Settings
No
Protocol
SW2-#1
SW2-#2
SW2-#3
SW2-#4
1
Samsung Techwin
OFF
OFF
OFF
OFF
2
Pelco-D
OFF
OFF
OFF
ON
3
Pelco-P
OFF
OFF
ON
OFF
4
Samsung Elec.
OFF
OFF
ON
ON
5
Panasonic
OFF
ON
OFF
OFF
6
Vicon
OFF
ON
OFF
ON
7
Honeywell
OFF
ON
ON
OFF
8
AD
OFF
ON
ON
ON
9
GE
ON
OFF
OFF
OFF
10
BOSCH
ON
OFF
OFF
ON
11
Reserved
ON
OFF
ON
OFF
12
Reserved
ON
OFF
ON
ON
13
Reserved
ON
ON
OFF
OFF
14
Reserved
ON
ON
OFF
ON
15
Reserved
ON
ON
ON
OFF
16
Reserved
ON
ON
ON
ON
Select a communication protocol for the camera
SW2 Pin No.
Purpose
1~4
Protocol Settings
5~6
Baud Rate Settings
7
Transfer Method (RS-485/422) Settings
8
Response Mode Settings
9
Backup Mode Settings 1
10~11
Termination Settings
12
Backup Mode Settings 2
* Coaxial communication automatically detects signals, and so does not require a separate
communication setup process.
* This model is provided with factory defaults of all DIP switches set to OFF. The default
settings are shaded in the table.