NOTE

: If you need to install ducts, note that the total 

duct length of 3 ¼˝ x 10˝ rectangular or 6˝ diameter 

round duct should not exceed 140 equivalent feet.

Outside ventilation requires a HOOD EXHAUST DUCT. 

Read the following carefully.

NOTE

: It is important that venting be installed using 

the most direct route and with as few elbows as 

possible. This ensures clear venting of exhaust and 

helps prevent blockages. 

Also, make sure dampers 

swing freely and nothing is blocking the ducts.

Exhaust connection:

The hood exhaust has been designed to mate with a 

standard 3 ¼˝ x 10˝ rectangular duct.

If a round duct is required, a rectangular-to-round 

transition adaptor must be used. 

Do not use less 

than a 6˝ diameter duct.

maximum duct length:

For satisfactory air movement, the total duct length of 

3 ¼˝ x 10˝ rectangular or 6˝ diameter round duct should 

not exceed 140 equivalent feet. 

Elbows, transitions, wall and roof 

caps, etc.,

 present additional resistance to airflow 

and are equivalent to a section of straight duct which is 

longer than their actual physical size. When calculating 

the total duct length, add the equivalent lengths of all 

transitions and adaptors plus the length of all straight 

duct sections. The chart below shows you how to 

calculate total equivalent ductwork length using the 

equivalent length in feet of some typical ducts.

DUCT PIECES

EQUIVALENT 

LENGTH

x

NUMBER 

USED

=

EQUIVALENT 

LENGTH

Rectangular-to-Round 

Transition Adaptor*

5 ft.

x

(    )

=

ft.

Wall Cap 

40 ft.

x

(    )

=

ft.

90 ° Elbow 

10 ft.

x

(    )

=

ft.

45 ° Elbow 

5 ft.

x

(    )

=

ft.

90 ° Elbow 

25 ft.

x

(    )

=

ft.

45 ° Elbow 

5 ft.

x

(    )

=

ft.

Roof Cap

24 ft.

x

(    )

=

ft.

Straight Duct 6˝ Round or 3 ¼˝ 

x 10˝ Rectangular

1 ft.

x

(    )

=

ft.

Total Ductwork

=

ft.

IMPORTANT

: If a rectangular-to-round 

transition adaptor is used, the bottom 

corners of the damper will have to be cut 

to fit, using tin snips, in order to allow free 

movement of the damper.

Equivalent lengths of duct pieces 

are based on actual tests and reflect 

the requirements for good venting 

performance with any vent hood.

NOTE: Read these next two pages only if you plan to vent your exhaust to the outside. If you plan to 

recirculate the air back into the room, proceed to page 11.

OUTSIDE TOP EXHAUST (EXAmPLE ONLY)

The following chart contains an example of one possible ductwork installation.

DUCT PIECES

EQUIVALENT 

LENGTH

x

NUMBER 

USED

=

EQUIVALENT 

LENGTH

Roof Cap

24 ft.

x

(1)

=

24 ft.

12 Ft. Straight Duct 

(6˝ Round)

12 ft.

x

(1)

=

12 ft.

Rectangular-to-

Round Transition 

Adaptor*

5 ft.

x

(1)

=

5 ft.

Equivalent lengths of duct pieces are based on actual tests 

and reflect requirements for good venting performance with 

any vent hood.

Total Length

=

41 ft.

*  IMPORTANT

: If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be 

cut to fit, using the tin snips, in order to allow free movement of the damper.

OUTSIDE BACK EXHAUST (EXAmPLE ONLY)

The following chart contains an example of one possible ductwork installation.

DUCT PIECES

EQUIVALENT 

LENGTH

x

NUMBER 

USED

=

EQUIVALENT 

LENGTH

Wall Cap

40 ft.

x

(1)

=

40 ft.

3 Ft. Straight Duct (3 ¼˝ 

x 10˝ Rectangular)

3 ft.

x

(1)

=

3 ft.

90 ° Elbow

10 ft.

x

(2)

=

20 ft.

Equivalent lengths of duct pieces are based on actual tests 

and reflect requirements for good venting performance with 

any vent hood.

Total Length

=

63 ft.

NOTE

: For back exhaust, care should be taken to align the exhaust with the space between studs, or the wall should 

be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.

HOOD EXHAUST

SMH1816_XAC_DE68-03943B-01_EN_120725.indd   4

2012-07-25   �� 7:50:44

Summary of Contents for SMH1816B

Page 1: ...hese instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical and electrical skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty READ CAREFULLY KEEP THESE INSTRUCTIONS This manual is made with 100 recyc...

Page 2: ...pting the microwave blower for recirculation 12 B2 Installing the charcoal filter 13 C Outside back exhaust horizontal duct 14 C1 Adapting the microwave blower for outside back exhaust 14 3 Installation 15 A Preparing the rear wall for outside back exhaust 15 B Attach the mounting plate to the wall 15 C Use the top cabinet template to prepare the top cabinet 16 D Mount the microwave oven 16 E Conn...

Page 3: ...oper ground exists before use Insure proper ground exists before use The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is...

Page 4: ...ular to round transition adaptor is used the bottom corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper OUTSIDE BACK EXHAUST EXAMPLE ONLY The following chart contains an example of one possible ductwork installation DUCT PIECES EQUIVALENT LENGTH x NUMBER USED EQUIVALENT LENGTH Wall Cap 40 ft x 1 40 ft 3 Ft Straight Duct 3 x 10 Rectangu...

Page 5: ...aps etc present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size When calculating the total duct length add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections The chart below shows you how to calculate total equivalent ductwork length using the equivalent length in fee...

Page 6: ...s x 2 1 Template INSTALLATION INSTRUCTIONS Toggle Bolts and wing nuts 3 16 x 3 2 Template INSTALLATION INSTRUCTIONS Self aligning Machine Screws 28 x 3 2 Template INSTALLATION INSTRUCTIONS Nylon Grommet for metal cabinets 1 You will find the installation hardware contained in a packet with the unit Check to make sure you have all these parts NOTE Some extra parts are included ADDITIONAL PARTS PART...

Page 7: ... 12 max NOTES The space between the cabinets must be 30 wide and free of obstructions This microwave oven is for installation over ranges up to 36 wide If you are going to vent your microwave oven to the outside see the Hood Exhaust Section for exhaust duct preparation If installing the microwave oven beneath smooth flat cabinets be careful to follow the instructions on the top cabinet template fo...

Page 8: ...rom the mounting plate This plate will be used as the rear wall template and for mounting NOTE You will have to reuse two screws in original loction of outcase after removing mounting plate B Finding the wall studs Wall Studs Center Center Wall Studs 1 Find the studs using one of the following methods A Stud finder a magnetic device which locates nails OR B Use a hammer to tap lightly across the m...

Page 9: ...nds below the cabinet Tape the Rear Wall Template onto the wall so that the top of the template touches the bottom of the horizontal line and the centerline on the template lines up with the vertical line s t Draw a vertical line on the wall at the center of the 30 wide space Tape the Rear Wall Template onto the wall so that the top of the template touches the bottom of the cabinet and the centerl...

Page 10: ...ingers on sharp edges 1 Draw a Horizontal line on the wall at the bottom of the Rear Wall Template 2 Drill holes for toggle bolts in 3 locations Hole A Hole B Hole C as shown in the illustration above If the location of a hole lines up with a stud drill a 3 16 hole for a wood screw You cannot use a toggle bolt to attach the wall plate to a stud NOTE DO NOT MOUNT THE PLATE AT THIS TIME 3 Holes A B ...

Page 11: ...haust adaptor is shipped assembled and attached to the filler upper Select the type of ventilation required for your installation and proceed to that section A Outside top exhaust vertical duct B Recirculating non vented ductless Adaptor in Place for Outside Top Exhaust Adaptor in Place for Outside Top Exhaust See page 12 See page 12 A Charcoal Filter Accessory Kit is required for the nonvented ex...

Page 12: ...cabinet and adjust the exhaust adaptor so that you can connect it to the house duct Back of Microwave Blower Plate Damper For Front to Back or Side to Side Adjustment Slide the Exhaust Adaptor as Needed For Front to Back Adjustment Slide the Exhaust Adaptor as Needed Blower Plate Back of Microwave Damper NOTE You must attach the house duct to the exhaust adaptor after installation is complete Hous...

Page 13: ...ore Roll After Roll Back of Microwave 5 Place the blower unit back into the opening CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched 6 Secure the blower unit to the microwave with the screw B2 Installing the charcoal filter 1 Remove the screws on the top of the grill using a 1 Phillips screwdriver 2 Open the door 3 Remove the grill Push the grill left and t...

Page 14: ...nterclockwise 180 Before Rotation After Rotation Back of Microwave Back of Microwave 6 Place the blower unit back into the opening AFTER Fan Blade Openings Facing Back End B End A CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched NOTE The blower unit exhaust openings should match exhaust openings on the rear of microwave oven 7 Close the Blower Plate and att...

Page 15: ...zontal duct only B Attach Mounting Plate to Wall C Prepare Top Cabinet D Mount the Microwave Oven E Connecting Ductwork vertical duct only A Preparing the rear wall for outside back exhaust You need to cut an opening in the rear wall for outside exhaust C L Read the instructions for outside back exhaust on the REAR WALL TEMPLATE Tape the REAR WALL TEMPLATE to the rear wall Cut the opening followin...

Page 16: ...CABINET TEMPLATE Tape it underneath the top cabinet Drill the holes following the instructions on the TOP CABINET TEMPLATE CAUTION Wear safety goggles when drilling holes in the cabinet bottom D Mount the microwave oven FOR EASIER INSTALLATION AND PERSONAL SAFETY WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN IMPORTANT Do not grip or use handle during installation NOTE If your cabinet is...

Page 17: ...abinet Bottom Shelf Microwave Oven Top Cabinet Front Filler Block Self Aligning Screw 4 Attach the microwave oven to the top cabinet 5 Insert the 2 self aligning screws through the cabinet bottom shelf and filler block into the outer top cabinet of the unit Continue to support the unit until both screws are inserted and engaged at least two full turns then fully tighten both screws until the unit ...

Page 18: ...lace the house fuse or turn the breaker back on Insure proper ground exists before use 5 Plug the power cord into a dedicated 15 amp electrical outlet Insure proper ground exists before use Insure proper ground exists before use 6 Read the Owner s Manual 7 Keep installation instructions for the local inspector s use 4 Before you use your microwave SMH1816_XAC_DE68 03943B 01_EN_120725 indd 18 2012 ...

Page 19: ...19 Note SMH1816_XAC_DE68 03943B 01_EN_120725 indd 19 2012 07 25 7 50 53 ...

Page 20: ...Code No DE68 03943B 01 SMH1816_XAC_DE68 03943B 01_EN_120725 indd 20 2012 07 25 7 50 53 ...

Page 21: ...ctions à l utilisateur Remarque destinée à l utilisateur Conservez précieusement ces instructions en vue d une consultation ultérieure Niveau de compétences L installation de cet appareil nécessite des connaissances mécaniques et électriques de base Il incombe à l installateur de poser correctement l appareil Tout dysfonctionnement imputable à une mauvaise installation n est pas couvert par la gar...

Page 22: ...cro ondes à la circulation en circuit fermé 12 B2 Installation du filtre à charbon 13 C Système d évacuation par l arrière conduit horizontal 14 C1 Adaptation du ventilateur du four micro ondes au système d évacuation par l arrière 14 3 Installation 15 A Préparation du mur du fond pour le système d évacuation par l arrière 15 B Fixation de la plaque murale 15 C Utilisation du gabarit du meuble hau...

Page 23: ... ÉLECTROCUTION Insure proper ground exists before use Assurez vous que le four est correctement mis à la terre avant de l utiliser Le cordon d alimentation de cet appareil est équipé d une prise tripolaire mise à la terre correspondant à la prise murale tripolaire standard mise à la terre afin de réduire le risque d électrocution Faites vérifier la prise murale et le circuit par un électricien qua...

Page 24: ... adaptateur rectangulaire circulaire est utilisé les coins inférieurs du registre devront être coupés à l aide de cisailles afin de le fixer et de permettre au registre de bouger librement SYSTÈME D ÉVACUATION PAR L ARRIÈRE EXEMPLE UNIQUEMENT Le tableau suivant contient un type d installation de conduits possible COMPOSANTS DE L ÉVACUATION LONGUEUR ÉQUIVALENTE x NOMBRE UTILISÉ LONGUEUR ÉQUIVALENTE...

Page 25: ...istance supplémentaire à la circulation de l air et sont équivalents à une partie de conduit droit plus long que leur véritable taille Lors du calcul de la longueur totale du conduit ajoutez les longueurs équivalentes de tous les raccords et adaptateurs à la longueur de toutes les parties de conduit droit Le tableau suivant vous indique comment calculer la longueur équivalente totale des conduits ...

Page 26: ...RUCTIONS Boulons à ailettes et écrous à oreilles 3 16 x 3 2 Template INSTALLATION INSTRUCTIONS Vis mécaniques autocentreuses 28 x 3 2 Template INSTALLATION INSTRUCTIONS Guide en nylon pour meubles en métal 1 L appareil est livré avec un sachet contenant le matériel d installation Vérifiez que vous disposez de toutes ces pièces REMARQUE certaines pièces supplémentaires sont incluses PIÈCES SUPPLÉME...

Page 27: ... meubles doit être de 30 et dégagé Ce four micro ondes est conçu pour être installé au dessus d une cuisinière de 36 de large Si vous souhaitez utiliser un système de ventilation pour le four micro ondes reportez vous à la partie Système d évacuation de la hotte pour la préparation du conduit d évacuation Lors de l installation du four micro ondes sous un meuble plat et lisse respectez les instruc...

Page 28: ...omme gabarit du mur du fond et pour le montage REMARQUE vous devrez réutiliser deux vis à leur emplacement d origine sur le châssis une fois la plaque de fixation retirée B Détection des montants Wall Studs Center Centre Montants 1 Recherchez les montants en utilisant l une des méthodes suivantes A Détecteur de montant appareil magnétique qui localise les clous OU B Utilisez un marteau pour frappe...

Page 29: ...s un meuble encastré avec débord frontal 30 de la surface de cuisson Tracez une ligne horizontale afin de marquer la distance dont la partie intérieure du débord frontal descend sous le meuble Si le meuble sur lequel vous souhaitez fixer l appareil comporte des ornements décoratifs ces derniers risquent de gêner l installation Retirez ces ornements pour assurer une installation et une mise à nivea...

Page 30: ...mur 2 Percez des trous de pour les boulons à ailettes à 3 emplacements trou A trou B trou C comme indiqué sur l illustration ci dessus Si l emplacement d un trou est aligné sur un montant percez un trou de 3 16 en vue de la pose d une vis à bois Les boulons à ailettes ne peuvent être utilisés pour fixer la plaque murale à un montant REMARQUE NE POSEZ PAS ENCORE LA PLAQUE À CETTE ÉTAPE DU MONTAGE 3...

Page 31: ... et fixé à la cale supérieure Sélectionnez le système de ventilation adapté à votre installation et reportez vous à la section correspondante A Système d évacuation par le haut conduit vertical B Circulation de l air en circuit fermé sans conduit et sans évents Adaptor in Place for Outside Top Exhaust Emplacement de l adaptateur pour une évacuation par le haut Reportez vous à la page 12 Reportez v...

Page 32: ...uit de l habitation Back of Microwave Blower Plate Damper For Front to Back or Side to Side Adjustment Slide the Exhaust Adaptor as Needed Pour un réglage avant arrière faites glisser l adaptateur du système d évacuation autant que nécessaire Plaque du ventilateur Arrière du micro ondes Registre REMARQUE vous devez fixer le conduit de l habitation à l adaptateur du système d évacuation après avoir...

Page 33: ...u micro ondes 5 Remettez le ventilateur dans son logement ATTENTION ne tirez pas sur les câbles du ventilateur Assurez vous que les câbles n ont pas été coincés au moment de la remise en place 6 Fixez le ventilateur sur le four micro ondes à l aide de la vis B2 Installation du filtre à charbon 1 Retirez les vis de la partie supérieure de la grille à l aide d un tournevis cruciforme nº 1 2 Ouvrez l...

Page 34: ...ntre Avant la rotation Après la rotation Arrière du micro ondes Arrière du micro ondes 6 Remettez le ventilateur dans son logement APRÈS ouvertures des ailettes du ventilateur dirigées vers l arrière Extrémité B Extrémité A ATTENTION ne tirez pas sur les câbles du ventilateur Assurez vous que les câbles n ont pas été coincés au moment de la remise en place REMARQUE Les ouvertures du système d évac...

Page 35: ...ge du four micro ondes E Connexion des conduits conduit vertical uniquement A Préparation du mur du fond pour le système d évacuation par l arrière Vous devez pratiquer une ouverture dans le mur du fond pour installer le système d évacuation C L Lisez les instructions relatives au système d évacuation par l arrière figurant sur le GABARIT DU MUR DU FOND Fixez le GABARIT DU MUR DU FOND au mur arriè...

Page 36: ...ble haut Percez les trous en respectant les instructions figurant sur le GABARIT DU MEUBLE HAUT ATTENTION portez des lunettes de sécurité pendant cette dernière opération D Montage du four micro ondes POUR PLUS DE FACILITÉ ET DE SÉCURITÉ LORS DE L INSTALLATION DE L APPAREIL DEUX PERSONNES SONT NÉCESSAIRES IMPORTANT évitez de saisir ou d accrocher la poignée du four pendant l installation REMARQUE ...

Page 37: ...o ondes Avant du meuble Cale Vis autocentreuse 4 Fixez le four micro ondes sur le meuble haut 5 Insérez 2 vis autocentreuses à travers le fond du meuble et des cales dans les trous extérieurs du meuble haut de l unité Continuez de maintenir l unité jusqu à ce que les vis soient insérées et engagées au moins deux tours complets puis serrez complètement les vis jusqu à ce que l unité soit fixée 6 In...

Page 38: ...ur sous tension Insure proper ground exists before use 5 Branchez le cordon d alimentation sur une prise dédiée de 15 A Insure proper ground exists before use Assurez vous que le four est correctement mis à la terre avant de l utiliser 6 Lisez le manuel d utilisation 7 Conservez précieusement ces instructions d installation afin que la personne chargée du contrôle local puisse s y reporter 4 Avant...

Page 39: ...19 Remarque SMH1816_XAC_DE68 03943B 01_CFR_120725 indd 19 2012 07 25 7 52 09 ...

Page 40: ...N de code DE68 03943B 01 SMH1816_XAC_DE68 03943B 01_CFR_120725 indd 20 2012 07 25 7 52 09 ...

Reviews: