Confidential and proprietary-the contents in this service guide subject to change without prior notice
Distribution, transmission, or infringement of any content or data from this document without Samsung’s written authorization is strictly prohibited.
8. Level 3 Repair
8-4-37. LTE B30 DRX
NORMAL CONDITION
catch the channel?
Check C2002
≤
-65dBm ?
Check C2082, C2083
≤
-65dBm ?
Check component soldering status OK at
F2002 ?
Check L2022
≤
-65dBm ?
Check C2048
≤
-65dBm ?
Check C2053
≤
-65dBm ?
Resolder or change
ANT2005 or ANT2001 or C2002
Resolder or change
C2082 or C2083 or C2002
Resolder or change
F2002
Resolder or change
L2022 or F2002
Resolder or change
L2022 or C2048
Resolder or change
U2010
Resolder or change
C2053 or U2010
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
Check component soldering status
OK at F2003 ?
Check C2054
≤
-65dBm ?
Resolder or change
F2003
Resolder or change
C2054 or F2003
NO
NO
YES
YES
Check the voltage at
C2049 = 1.8V &
Check component soldering status OK at
U2010 ?
Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.