8. Level 3 Repair
8-4-17. IRIS CAMERA
“Camera” function does not work
Yes
No
Reconnect the HDC10002
Yes
END
Yes
No
Resolder or Replace U10001
Yes
No
Reconnect the PBA
Yes
Replace the camera module
Check the Camera module
Connection
Check the IRIS_MCLK is
24 Mhz (C10000)
Yes
No
Resolder or Replace U7002
Check the voltage
C10009 : 1.2V , C10008 : 1.8V
Check the voltage
C10010 : 2.8V
Yes
No
Reconnect or Replace the Sensor FPCB
Check the Sensor FPCB
Connection