05 MENU SETUP
menu setup _
31
EVENT RECORD MODE
The detailed list for event mode settings is as
follows:
Alarm Detection Setup
Sensor State
- Off: Sensor does not operate.
- N.O (Normal Open): Sensor remains open
all the time. But if it gets closed, an alarm is
issued. (A Contact)
- N.C (Normal Close): Sensor remains closed
all the time. But if it gets open, an alarm is
issued. (B Contact)
Cam
It is used to set a camera that synchronizes
with the current sensor. The default setting
follows the sensor number. A sensor can
synchronize with multiple cameras so multiple
values can be selected.
You can set a preset for each camera to
synchronize sensors with cameras. If a sensor
triggers the corresponding camera, the camera
can show you the preset location.
Alarm-Out
It is used to set the Alarm-Out location when
any alarm occurs. Currently 5 Alarm Outs are
available. Select an alarm-out to synchronize
with the current sensor. But multiple values can
be selected.
Duration
It is used to set the Alarm-Out duration. When
an alarm occurs, the alarm is output for the
preset time. You can select any of Off, 3sec,
5sec, 10sec, 20sec, 30sec, and Continuous.
In case of SHR-5082/5080, only 8
channels are displayed.
Motion Detection Setup
You can configure the motion detection related
settings. When the detection area is set, the
system detects any motion in that area.
M.D State
- Off: Motion detection does not operate.
- On: Motion detection is active.
Area
This is used to set the motion detection
area. It is not allowed to set 4 extreme rows
(Up, Down, Left, Right) because the display
boundary regions can vary according to the
monitor specification.
- Select All: Selects the whole area.
- Select One: Selects a block unit for each
time.
- Select Quarter: Selects a quarter unit of the
screen for each time.
- Clear All: Clears the whole selection.
- Save & Exit: Saves the setting and exits.
- Exit: Exits without saving.
MENU
Select All
Select One
Select Quarter
Clear All
Save & Exit
Exit
Cancel
OK
Motion Detection Setup
Cam
M.D State
Area Sensitivity Alarm-Out Duration
1
Off
Set
Very High
None
10sec
2
Off
Set
Very High
None
10sec
3
Off
Set
Very High
None
10sec
4
Off
Set
Very High
None
10sec
5
Off
Set
Very High
None
10sec
6
Off
Set
Very High
None
10sec
7
Off
Set
Very High
None
10sec
8
Off
Set
Very High
None
10sec
9-16
Cancel
OK
Alarm Detection Setup
Sensor State
Cam
Alarm-Out
Duration
1
Off
1
None
10sec
2
Off
2
None
10sec
3
Off
3
None
10sec
4
Off
4
None
10sec
5
Off
5
None
10sec
6
Off
6
None
10sec
7
Off
7
None
10sec
8
Off
8
None
10sec
9-16
MENU SETUP
System
Camera
Monitoring
Record Mode
Event Record
Schedule
Backup
Network
Alarm Detection Setup
Motion Detection Setup
Video Loss Detection Setup
Move/Control
Select
Exit
SHR-5162_Eng.indb 31
2007-8-2 14:47:41