Motion Detection, Unknown Location
(0x08)
Emergency
(0x0A)
Contact Police (0x01)
Contact Fire Service (0x02)
Configuration (V1)
Name
Parameter
Number
Size
Value
Description
Security Function 0x01
1byte
0x00
0x01
0x02
0x03
0x04
0x05
Disable (Default)
Enable
System Disable
1)
System Enable
1)
Request for Enable
1)
Fail
1)
Privacy Mode
0x02
1byte
0x00
0x01
Disable (Default)
Enable
Registered User
ID
0x03
1byte
1 ~130
The number of registered user codes.
2)
Platform
0x0A
1byte
0x00
0x01
Common (Default)
Samsung SDS
3)
1)
This value can be used when the device is connected with platform of Samsung SDS.
This function is not related to Z-Wave CC.
- 0x02 : Command for disable which is set by platform of Samsung SDS.
After setting, if you try to get value of Security Function , '0x00' will be reported.
- 0x03 : Command for enable which is set by platform of Samsung SDS.
After setting, if you try to get value of Security Function, '0x01' will be reported.
- 0x04 : 'Request for Enable' command which is reported by Doorlock. This cannot be set.
(8th function in manual)
- 0x05 : If the request for 'Request for Enable' command is failed in platform,
this will be set by platform of Samsung SDS.