Smart
Door Lock
SHN-WDD510
4. Installing the Magnetic Sensor
Install the door side magnetic sensor.
It should be installed in right way of the door.
CAUTION
: The gap of the magnet sensors
between the door side and the door-frame should
be within 3/4”(20mm). If the gap is to wide, pull out
the door side magnetic sensor to adjust the gap
enough to detect.
5. Connecting the cable
B
REG
SET
3. Installing the Mounting Plate
1. Detach the Interior Mounting Plate from
the interior unit.
2. Fasten the interior mounting plate with
three TH+M5x40 (G2) 90% of the way.
3. Align the Exterior Unit with the Interior
Mounting Plate and then tighten the
screws.
4. Cover the rubber pad on the Interior
Mounting plate.
CAUTION
: Do not over-tighten, and check
the movement of dead bolt by the mechani-
cal key.
C
C
G2
3/4˝(20mm)
SET
REG
REG
Left-handed
Right-handed
1. Connect the cable from the exterior unit
to the interior unit.
2. After connecting the cable, push the
cable into the hole of the door.