3-1-5. Microphone Part
Microphone does not work
Check the assembled status of
microphone
Check the reference voltage on
mic path R419=2.9V
END
Reassemble microphone
Resolder or Change
(R413,R414,R415,R416,R417,R418,
R419,C420,C421,C422,C423,C424,
L401,L402,TA402,VR400,VR401)
Check UCP300
Is Microphone O.K?
YES
YES
YES
YES
NO
NO
NO