Maintenance & Troubleshooting
7-4
Samsung Electronics
7-2-3 Maintenance List
A number of reports can be printed from the fax
machine within the test mode. The protocol list
and memory dump list all contain detailed
information which may be required when
contacting technical support.
To printout the protocol and memory dump lists:
1. Get into the Tech mode by pressing
MENU
,
#
,
1
,
9
,
3
,
4
.
2. In Tech mode, press
MENU
, and one-touch 16
'TX. CONFIRM'.
3. Press
▼
or
▲
repeatedly until you find the
Protocol Dump List. When you find
'
PROTOCOL REPORT?
', press
ENTER
.
Remote Diagnostics on the dex 825 is preformed
by a remote PC. The dex 825 has to be conditioned
o that remote PC can perform remote diagnostics.
1. Press
MENU
, One-touch 04 'SYSTEM SETUP'.
2. Press
▲
or
▼
until
'REMOTE DIAGNOSIS
PROTECTION ?'
is displayed.
3. Press
ENTER
.
4. Press
1
for protection or press
2
to allow remote
diagnosis.
5. Press
ENTER
.
6. Press
STOP
to exit routine.
S NSF 61005020003380140200001302090018010000
S/R FCF FIF DATA ASCII
S CSI 2020202020202020202020202O20202020202020
S CSI 202020202020202020202022O202020220202020
R TSI 2020202020202020202020202O20202020202020
S DIS 00000000 01110111 00010111 00100010
S DIS 00000000 01110111 00010111 00100010
R DCS 00000000 01100001 00010101 00000000
R TSI 2020202020202020202020202O20202020202020
R DCS 00000000 01100001 00010101 00000000
S CFR
R MPS
S MCF
S DCN
S FTT
S NSF 61005020003380140200001302090018010000
PROTOCOL DUMP LIST
AUG-20-94 06:35
Sending/Receiving
Name of signal
(Facsimile Control Field)
Facsimile Information Field
data described in hexdecmal code
FIF data described
in ASCII code
SAMPLE OF A PROTOCOL DUMP LIST
7-3 Remote Diagnostics and Control