TROUBLESHOOTING
•
Troubleshoot the conventional wired telephone
In the event you are unable to place or receive telephone calls, first be sure
that the connetion wire is properly connected to the RJ-11 phone port on the
terminal and to the RJ-11 port of the telephone. If unsure whether or not the
telephone is operational, connect a telephone which is known to be
operational to the terminal.
If service is available with the operational telephone, replace or repair your
telephone equipment. If service is still not available, then follow instructions
under "Troubleshoot the Fixed Wireless Terminal".
•
Troubleshoot the Fixed Wireless Terminal
Check for the appropriate power indication on the LED. If no power, check
the Adaptor(or External Power Supply)connection between the electrical
outlet and the terminal. Check for the appropriate Received Signal Strength
Indication(RSSI), Power, and Message Indication through the designated
LED, respectively.
SPECIFICATIONS
Frequency Range
Tx : 825-849 MHz
Rx : 870-894 MHz
Channel Bandwith
CDMA 1.25 MHz
Multi Connection
Supports 5 REN
RJ-11 Phone Port
SCW-R500 : 3
SCW-R510 : 2
RJ-11 Analog Fax Port
SCW-R510 : 1
Power Supply
DC 9V 1.2A
Temperature of operation
-20°C~ +50°C
Relative humidity
5% ~ +95%
Temperature of storage
-25°C ~ +75°C
Dimension
200x170x48.5 (mm)
7.9x6.7x1.9 (in.)
Weight
495g / 1.1 lb.
(without external adaptor)
SCW-R500 1/9/99 12:06 PM Page 22