S3F84B8_UM_REV 1.00
21 ELECTRICAL DATA
21-5
Table 21-4 Oscillator Characteristics
(T
A
= –40
C to + 85
C)
Oscillator
Clock Circuit
Test Condition
Minimum
Typical
Maximum
Unit
V
DD
= 2.7 to 5.5V
0.4 – 10
MHz
V
DD
= 2.0 to 2.7V
0.4 – 4
MHz
Main crystal or
ceramic
X
IN
X
OUT
C1
C2
V
DD
= 1.8 to 2.0V
0.4 – 2
MHz
V
DD
= 2.7 to 5.5V
0.4 – 10
MHz
External clock
(Main System)
X
IN
X
OUT
V
DD
= 1.8 to 2.7V
0.4 – 4
External RC
oscillator
–
V
DD
= 5.0V
– 8 –
MHz
–
Factory calibrated at
25
C, 5.0V
– – ±3
%
–
V
DD
= 5.0V
T
A
= –40
C to + 85
C
– – ±6
%
Tolerance of
Internal RC
–
V
DD
= 2.0 to 5.5V
T
A
= –40
C to + 85
C
– – ±9
%
NOTE:
, “Operating Voltage Range @ External clock”.