CLOCK CIRCUIT
7-5
CLOCK OUTPUT CONTROL REGISTER (CLOCON)
The clock output control register, CLOCON, is located in the bank 0 of set1, address E3H. It is read/write
addressable and has the following functions;
— Clock Output Frequency Selection
After a reset, fxx/64 is select for Clock Output Frequency because the reset value of CLOCON.1-.0 is "0".
Clock Output Control Register (CLOCON)
E3H, Set 1, bank 0, R/W
.7
.6
.5
.4
.3
.2
.1
.0
MSB
LSB
Clock Output Frequency Selection Bits:
00 = fxx/64
01 = fxx/16
10 = fxx/8
11 = fxx/4
Not used for the S3C80M4
Figure 7-6. Clock Output Control Register (CLOCON)
CLOCON.1-.0
CLKOUT
MUX
fxx/64
fxx/16
fxx/8
fxx/4
P1CONH.5-.4
Figure 7-7. Clock Output Block Diagram