Operations
English
50
Oper
ations
SMART GRID Function (Demand Response)
When the refrigerator operates in SMART GRID (Demand Response) mode, the Energy
Management Refrigerator function can control energy usage or delay the operation of
some functions to save money when energy prices or demand are the highest.
NOTE
• You can deactivate the SMART GRID (Demand Response) function at any time using the
Peak Demand Off function.
• To use the SMART GRID (Demand Response) function, you need a separate contract with
your electric utility company.
In addition, to use the SMART GRID (Demand Response) function, you must register for the
service with your electric company. The company must have an EMS (Energy Management
System) that supports SEP (Smart Energy profile).
Using the SMART GRID (Demand Response) Function
This feature monitors energy prices and demand information from your utility company
and sends notifications to the refrigerator to run high energy consuming tasks during off-
peak times when electricity costs and demand are lower.
If the refrigerator receives a control signal from the utility company, the refrigerator will
display the
DAL
(L3) ~
TALR
(L4) levels on the refrigerator display and control the power
consumption according to the level.
[Exception condition] The
DAL
and
TALR
control signals from a utility company work as
long as product performance is maintained.
If the refrigerator receives the SMART GRID (Demand Response) signal (
DAL
or
TALR
), the
refrigerator will operate in Delay Appliance Load (Display:L3) or Temporary Appliance Load
Reduction (Display:L4) mode.
• Delay Appliance Load (L3): The refrigerator responds to a
DAL
signal by providing a
moderate load reduction for the duration of the delay period. This function controls
functions that consume a lot of energy such as adjusting the Cooling system and
running the defrost cycle.
- When the refrigerator operates in
DAL
(L3) mode, “L3” is displayed on the
refrigerator display.
-
DAL
mode is automatically deactivated after it lasts for the amount of time stipulated
by the
DAL
signal (max. 4.5 hours) or when the Peak Demand Off (
Preserve
for the
middle compartment) button is pressed.
• Temporary Appliance Load Reduction (L4): The refrigerator responds to a
TALR
signal
by aggressively reducing the load for a short time period. This function reduces energy
consumption by stopping the compressor and controlling the functions that consume a
lot of energy such as the defrost cycle.
- When the refrigerator operates in
TALR
(L4) mode, “L4” is displayed on the
refrigerator display.
-
TALR
(L4) mode is automatically deactivated after it lasts for the received duration
(max. 15 minutes), or when the Peak Demand Off (
Preserve
for the middle
compartment) button is pressed. The mode is immediately deactivated and the
refrigerator returns to the normal state when the door is opened or closed, or the
dispenser is used.
Untitled-3 50
2020-11-12 4:06:01
Summary of Contents for RQ48 Series
Page 1: ...Refrigerator User manual Free Standing Appliance Untitled 3 1 2020 11 12 4 05 42 ...
Page 157: ...Notas Untitled 5 77 2020 11 12 4 24 09 ...
Page 158: ...Notas Untitled 5 78 2020 11 12 4 24 09 ...
Page 159: ...Notas Untitled 5 79 2020 11 12 4 24 09 ...
Page 161: ...Réfrigérateur Guide d utilisation Appareil amovible Untitled 4 1 2020 11 12 4 19 51 ...