Setting an indoor unit address and installation option
◆
Switch the system on and wait for code " " to appear on the display of
the external unit (this requires approximately 60 seconds **).
◆
As soon as code " "displays, press once the red button (K1) shown on
the figure on the side of the page:
◆
After the operations described above have been performed, the system starts in Cooling or
Heating mode, depending on the external ambient temperature. After a few minutes (from a
minimum of 3 to 5 minutes for the internal unit), the system stops automatically, completing
the self-test and addressing procedure.
" " appears on the display of the external unit.
◆
20 seconds after the display of " " (that confirms the correct execution
of the procedure), the following codes (if four internal units are connected) dis
play in sequence on the display of the external unit:
Display 1
Display 2
Description
The outdoor unit is communication correctly together the
indoor unit connected to refrigerant pipe A.
The outdoor unit is communication correctly together the
indoor unit connected to refrigerant pipe B.
The outdoor unit is communication correctly together the
indoor unit connected to refrigerant pipe C.
The outdoor unit is communication correctly together the
indoor unit connected to refrigerant pipe D.
At this point it is possible to start the internal units in the desired mode
≫
If " "doesn’t display, the procedure has failed and it is therefore necessary to read
ALL the operator’s manual before repeating the operating described in steps 1-2-3-4.
Display of the external unit
※
During the initial 60 seconds,
display 1 shows in sequence:
00
→
01
→
02
→
...15
→
00...
If the quantity of indoor units connected is lower than maximum
connectable to outdoor unit, the rotary switch SW01 has to be
positioned, in order to select a number equal to indoor units’
quantity you connected.
WARNING
RJ040F2HX**/RJ050F2HX**
RJ060F3HX**/RJ070F4HX**
RJ080F4HX**
SW0 2
This product is prohibited one indoor unit installation. Don't use pipe
checking operation and Auto Addressing Mode when one indoor
unit is installed.
CAUTION