53
TROUBLESHOOTING
2) If R Sensor has trouble
Bad contact of connector/ insert correctly
Is MAIN PCB
Connector CN30 to CN75 inserted
correctly?
Is R Sensor
unit normal?
Is the voltage between
MAIN PCB Connector CN30#6(White) to
CN1#3(Black) normal?
Is the input voltage to
IC01 MICOM #54 normal?
Start
NO
YES
YES
YES
YES
Replace the temperature sensor
NO
Recheck the wire connection part
NO(0.6V > Measurement < 4.6V)
Check the iced-solder, solder bridging,
disturbed solder.
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connection.
** Measuring point of resistance value according to
Sensor **
R : CN30#6
CN75#1 measuring resistance value
** 0 : Short trouble /
: Open trouble
Sensor MICOM/Connector number
Voltage measured between 4.6V ~ 0.6V.
Measuring voltage IC01 MICOM #54,
CN30#6(White) and CN1#3(Black)
from PCB typical Ground part are similar.
Checking method of R Sensor resistance
CN30#6(White)
CN75#1(Gray) Compare the
temperature table after the measure.
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
R
Connector CN30#6(White) to
CN1#3(Black) PCB typical Ground
Checking method of R Sensor resistance
- Measure the voltage of Sensor Check Point #3(IC01 MICOM #54)
on PCB or CN30#6(White)
CN1#3(Black)
- Compare the temperature table after the measure.
Measuring voltage of CN30#6(White)°ÍCN1#3(Black) are below.
typical PCB Ground
CN#3(Black)
Summary of Contents for RF265AARS RF266AARS RF26NBRS1RF265AABP RF266AABP RF26NBBP1RF265AAWP RF266AAWP RF26NBSH1RF265AASH...
Page 2: ......
Page 19: ...18 Refrigerator PRODUCT SPECIFICATIONS 2 9 Cooling Air Circulation Freezer ...
Page 120: ...119 8 1 Whole block diagram 8 Shematic Diagram AC115V AC115V AC115V 8 1 1 MODEL RF266 BETTER ...
Page 121: ...120 Shematic Diagram AC115V AC115V AC115V 8 1 2 MODEL RF265 GOOD RF26NB ...
Page 122: ...121 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 1 Sheet 1 of 2 ...
Page 123: ...122 8 2 CIRCUIT DIAGRAM Shematic Diagram 8 2 2 Sheet 2 of 2 ...