Locating the Units
Do not install the Air to Water Heat pump in following places.
- The place where there is mineral oil or arsenic acid.
There is a chance that parts may get damaged due to burned resin.
The capacity of the heat exchanger may reduce or the Air to Water Heat pump may be out of order.
- The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet
The copper pipe or connection pipe may corrode and refrigerant may leak.
- The place where there is a danger of existing combustible gas, carbon fiber or flammable dust.
The place where thinner or gasoline is handled.
Do not install the outdoor unit in a snowy and cold area (low temperature and high humidity
area - where the temperature is below -7°C and humidity is higher than 85%) because
according to operation condition (defrost, etc.), ice may be formed in the drain route.
If the ice is accumulated, it may cause critical damage to the product.
ex) lakeside of cold area in winter time, seashore, alpine region and etc.
Avoid a place that may disturb your neighbor. Noise may occur from the outdoor unit and the
discharged air may run into the neighborhood.
(Be careful of the operation time in a residential area.)
Install the outdoor unit on a hard and even area that can support its weight.
Choose a flat place that rainwater does not settle or leak.
Choose a place avoiding strong winds.
Maintain sufficient space for repairs and service.
Choose a place where you can easily connect the pipes and cables to the indoor unit.
Make sure that the condensed water dripping from the drain hose runs out properly and safely.
If you install the outdoor unit by the sea or a spa, concern about corrosion.
Build a support where may have a heavy snow so that the air intake is not blocked by snow.
Install a protective safety fence to eliminate the possibility of falling.
You have just purchased Air to Water Heat pump and it has been installed by your
installation specialist.
This device must be installed according to the national electrical rules.
With an outdoor unit having net weight upper than 60kg, we suggest do not install it
suspended on wall, but considering floor standing one.