42
Temp Control &Operation Functions
2) After changing to the Option Mode,the display panel will blink "0"(ALL OFF)for R-Room and "0"(ALL OFF)for
F-Room. (When sending out products, there shall be "0"set for R-Room and "0"set for F-Room.
But,for the purpose of quality improvement,the standard set values can be changed.)
- If only "0"for R-Room blinks,F-Room temp option item will be set and the current F-Room temp set value will
be shown on the temp display of F-Room.
3) After setting "0"for R-Room and selecting "6"as in the option table of F-Room below, the standard temp of F-
Room will be lowered by 28.4
℉
(-2.0
℃
). (Refer to F-Room temp change figure)
4) The above option setting method is the same for all models whether they have Ice Maker or not.
5) With the same as the above method,R-Room Temp,Water Supply Qty, Ice Maker Eject Temp/Time,Defrost
Restoration Temp, Hysteresis & Notch Gap for each temperature can be controlled.
6) Since option is already set in EEPROM while sending out products at the factory, do not change it randomly
except for special occasions and do not turn off power before restoring to the normal display because option
will be completed when it is restored to the normal display in 20 seconds.
: In 20 seconds after the completion of the
adjustment,MICOM will store the set value in EEPROM
and it will be restored to the normal display and the option
setting mode will be cancelled.
Option Value
Option Item
Note
Basically,when sending out products,their option will be all cleared. That is,their set values are all “0”.
However, for the purpose of quality improvement, set values could be changed. Therefore, make sure to
check quality information
Note
There are other options including the functions mentioned above. But, they are related to the refrigerator
controlling.They are dropped here since they are not relevant to A/S.
(Do not set other options except for those in this A/S manual.)