TROUBLESHOOTING
6) If F DEF Sensor has trouble
Bad contact of connector/Insert correctly
Is Main PCB Connector
CN30 inserted correctly?
Is F DEF Sensor unit normal?
Is the voltage between
Main PCB Connector CN30-#6(Pink) and REG1,
Heat Sink normal?
Is the input voltage of IC10
MICOM #58 normal?
Start
NO
YES
YES
YES
YES
Replace temperature sensor
NO
Check the wiring connection.
NO (0.6V > Measurement < 4.6V)
Check Cold solder joint,
Short, Solder Touch
NO
No trouble with PCB and temperature sensor.
Recheck the bad contact of the connector.
** Measuring point of resistance value according
to Sensor **
F-DEF : CN30 #6
↔
#8 Measure the resistance value
**
∞Ω
: Short trouble /
∞Ω
: Open trouble
Sensor MICOM/Connector number
Voltage is measured between 4.6V ~ 0.6V
Voltage of IC10 MICOM #58 is same with the
measuring voltage of CN30-"6"(Pink) and REG1,
& Heat Sink from PCB common Ground part.
→
Check the measure on MICOM or, Sensor
Marking #4(R307).
DATA1.
Temperature table
ERROR Code
Refer to circuit diagram in the manual
F DEF Connector CN30-#6(Pink) and REG1
Heat-Sink PCB commonGround
Start
YES
YES
YES
☞
Checking method of F DEF Sensor resistance
CN30-#6(Pink)
↔
#8(Gray)
-. Compare with the temperature table after
measuring.
☞
Checking method of F DEF Sensor voltage
-. Measure the voltage of Sensor Check Point #4(IC10 MICOM
#58) on PCB or CN30-"6"(Pink)
↔
REG1, Heat Sink.
-. Compare with the temperature table after measuring.
Below is the measuring voltage of CN30-"6"(Pink)
↔
REG1, Heat Sink
Common PCB
Ground of REG1 Heater Sink
NW-미주향-AC 2010.6.8 3:47 PM 페이지48 in
Summary of Contents for RB195ACBP
Page 16: ...16 PRODUCT SPECIFICATIONS 2 8 Cooling Air Circulation NW 미주향 AC2010 6 83 46PM페이지16 in ...
Page 93: ...93 7 Wiring Diagram NW 미주향 AC2010 6 83 48PM페이지93 in ...
Page 94: ...94 8 1 Refrigerator Block Diagram 8 Schematic Diagram NW 미주향 AC2010 6 83 48PM페이지94 in ...
Page 95: ...95 8 2 Power and Signal Block Diagram SchematicDiagram NW 미주향 AC2010 6 83 48PM페이지95 in ...