36
TROUBLESHOOTING
Load mode Check list
Display LED
R-1-
ⓐ
R-1-
ⓑ
R-1-
ⓒ
R-1-
ⓓ
R-1-
ⓔ
R-1-
ⓕ
R1-
ⓖ
F-1-
ⓐ
F-1-
ⓑ
F-1-
ⓒ
F-1-
ⓓ
R-10-
ⓔ
R-10-
ⓕ
Display contents
R-FAN High
R-FAN Low
R-DEF Heater
Start Mode
Overload condition
Low temperature condition
Normal Condition
Exhibition Mode
COMP.
F-FAN High
F-FAN Low
F-DEF Heater
C-FAN High
C-FAN Low
Operation contents
When fresh food compartment FAN High operates,
applicable LED ON.
When fresh food compartment FAN Low operates,
applicable LED ON.
When fresh food compartment defrost heater operates, LED ON.
When initial power applied to refrigerator, LED ON.
When ambient temperature is more than 93
℉
(34
℃
), LED ON.
When ambient temperature is less than 72
℉
(22
℃
), LED ON.
When the ambient temperature is between
73
℉
(23
℃
) ~ 91
℉
(33
℃
).
F-1-
ⓔ
,
ⓕ
ALL LED Off
At the display mode, LED ON.
When compressor operates, applicable LED ON.
When freezer FAN High operates, applicable LED ON.
When freezer FAN Low operates, applicable LED ON.
When freezer defrost heater operates, LED ON.
When compressor FAN High operates, applicable LED ON.
When compressor FAN Low operates, applicable LED ON.
NW-미주향-AC 2010.6.8 3:47 PM 페이지36 in
Summary of Contents for RB195ACBP
Page 16: ...16 PRODUCT SPECIFICATIONS 2 8 Cooling Air Circulation NW 미주향 AC2010 6 83 46PM페이지16 in ...
Page 93: ...93 7 Wiring Diagram NW 미주향 AC2010 6 83 48PM페이지93 in ...
Page 94: ...94 8 1 Refrigerator Block Diagram 8 Schematic Diagram NW 미주향 AC2010 6 83 48PM페이지94 in ...
Page 95: ...95 8 2 Power and Signal Block Diagram SchematicDiagram NW 미주향 AC2010 6 83 48PM페이지95 in ...