4-28
Samsung Electronics
Troubleshooting
1. Waveform slope adjustment
2. Rising slope
1) Extend 1st Sub-Field of Preset Rising Part.
2) Adjust the scale of scope to 50V, 10us
division.
3) Adjust waveform just like the following
C(rising edge), D.
3. Falling slope
1) Extend 1st Sub-Field of Main_Reset Falling
Part.
2) Adjust the scale of scope to 50V, 10us
division.
3) Adjust waveform just like the following
C(falling edge), D.
<Y Board 1st. Subfield waveform>
A
B
D
C
Yfr interval
Yff interval