48
E.3-7 Strobe Error
NO YES
NO
YES
NO
YES
YES
NO
NO
NO
YES
YES
NO YES
NO
YES
Bad Charger to Big
cap
Big Cap Connect
Error (+,- reverse)
Check Flash tube is
Burned?
Replace Flash tube
Check Flash tube:
wire connect to TOP
BD is good or not
Replace / Resold
wire
Flash tube not
install well
Correction to right
position
Swap connect
Check TOP BD
〝
CHARGE
〞(TP8) singal
is Low(when trigger
signal is high)
Check TOP BD
〝
C7
〞
voltage is around
300V
Check T/B
〝
STROBE-
TRIGGER
(TP3)
signal
is Hi→Lo
Check TOP BD
T1
、
D3 is cold
soldered or damaged
Check TOP BD J1
or Digital BD J2
is cold soldered
Check TOP BD T2
and Q5 are cold
soldered
Resoldered TOP BD
J1 or Digital BD
J2
Resoldered or
Replace TOP BD
T1
、
D3
Resoldered TOP
BD T2 and Q5