Summary of Contents for OM75R

Page 1: ...not provide warranty coverage forproblems that may arise as a result of failure to follow the guide The colorand shape of the product mayvary In addition instructions in the installation guide may change without priornotice when necessary to improve the product Window Display Installation Manual ...

Page 2: ...tion Precautions for installation 3 Rotation and tilt angle 3 Clearance for installation 4 Installing the wall mount 6 Air flow direction 7 02 Enclosureunitdesignguide Inlet and outlet types 8 Vent opening design guide 8 Partition design guide 9 ...

Page 3: ...ll this product near machinery that works with oil Oil mist may cause fans to malfunction Do not use tempered glass e g touchscreen glass on the front of the panel Temperature increase due to tempered glass may cause a malfunction of the display which is not covered by the display warranty Rotationandtiltangle Contact Samsung CustomerService Centre forfurtherdetails 15 The display can be used in l...

Page 4: ...least100 mm B ambient temperature measuring point below30 C If the unit is subjected to excess heat due to an insufficient gap this maycause a malfunction whichwill not be covered bythewarranty To use an enclosure make sureyou contact Samsung Electronics forassistance An enclosure maycause the display temperature to increase Air conditioner A B English 4 OM75R ...

Page 5: ...e exceed 30 C A B Requiredclearancewheninstallinganenclosure When installing the displayalongwith an enclosure ensure adequate clearance A between the back of the enclosure and surrounding objects forproperflowof air Example1 Exposure to direct sunlight 100 mm ormore Example 2 Atmospheric temperatures under35 without direct sunlight 50 mm ormore If the unit is subjected to excess heat due to an in...

Page 6: ...here should also be a clearance of at least100 mmwhen using awall mount not made bySamsung Since the set screwdepth is 46 mm you should select an M8 screwthat is longerthan 46 mm considering the thickness of the mount 13 0 28 100 13 3 35 5 10 8 46 WMN6575SE Optional bracket OM75R Wall Wall mountWMN6575SE Width mm 564 Height mm 580 Depth mm 100 Weight kg 4 4 VESAstandard mm 400 x 400 English 6 OM75...

Page 7: ...inlet to lowerthe internal temperature of the displayand discharges thewarmed airthrough the airoutlet When designing an enclosure orinstalling the display make sureyou remove anyobstacles that mayinterferewith the flowof airat the airinlet oroutlet Airoutlet Airinlet Sideview Back English 7 OM75R ...

Page 8: ... in this guide are not observed the cooling system maynotwork properlyand maycause a malfunction whichwill not be covered bywarranty The opening ratio should be minimum 50 Calculating Total open area of theventilation andVentilation opening ratio Total Area of theVentilation 181 x 89 16 109 mm Total open area ofVentilation holes 20 x 20 x 32 12 800 mm 181 mm 3 mm 20 mm 89 mm Ventilation opening ra...

Page 9: ...owscreen around the 4 sides of the edges of the protrusion on the rearcover When installing the displayalongwith an enclosure ensure adequate clearance A between the back of the enclosure and surrounding objects forproperflowof air Example1 Exposure to direct sunlight 100 mm ormore Example 2 Atmospheric temperatures under35 without direct sunlight 50 mm ormore If the unit is subjected to excess he...

Page 10: ...and outlet to match the locations of the semi outdoorunit inlet and outlet Allowclearance of 50 mm ormore between the product and the enclosure unit Total open area ofVentilation holes Totalopenareaof Ventilationholes Airoutlet 20 000 mm ormore each 20 000 mm ormore each Airinlet 20 000 mm ormore each 20 000 mm ormore each When installing an enclosure referto the Required clearancewhen installing ...

Page 11: ... displays side byside in landscape orientation make sureyou install separate fans as shown below to maintain a flowrate of at least150 CFM so as to prevent the displays from being affected byone another due to the intake exhaust air The external airtemperature should be maintained below30 C as shown below measured position B If the unit is subjected to excess heat due to an insufficient gap this m...

Page 12: ...side enclosure make sureyou install a separate fan as shown below to maintain a flow rate of at least 300 CFM considering that there is no inlet on the rear The external airtemperature should be maintained below30 C as shown below measured position B Make sure the lowerinlet is large enough to not cause the fan flowrate to decrease If the unit is subjected to excess heat due to an insufficient gap...

Reviews: