Partition design guide
• For semi-outdoor units, add partitions between the inlet and outlet to keep air paths separated.
• Partitions should fit perfectly inside the enclosure unit, with no gap between the semi-outdoor unit and enclosure
unit. If there is a gap, use a foam tape to fill it.
Partition
Foam tape
• Install an anti-backflow screen around the
4
sides of the edges of the protrusion on the rear cover.
• When installing the display along with an enclosure, ensure adequate clearance (
A
) between the back of the
enclosure and surrounding objects for proper flow of air.
–
Example
1)
Exposure to direct sunlight: 100 mm or more
–
Example
2)
Atmospheric temperatures under 35
℃ without direct sunlight:
50 mm or more
–
If the unit is subjected to excess heat due to an insufficient gap, this may cause a malfunction, which will not be
covered by the warranty.
A
Wall
English - 9
OM75R