OH85N/(LH85OHNSKGB/**)
Connecting the power cable
–
The color and the appearance may differ depending on the product, and specifications are subject to change without
prior notice to improve the performance.
Distribution
switchboard
Make sure that you have a 8.5 mm diameter waterproof power cable that can
withstand 1800 W or higher.
–
The power cable must be connected to a 20 A or higher amperage circuit.
Connect the two power cables by soldering and insulate the area.
Place the soldered (connected) part of the cable inside the product.
Place the back cover and fasten the screws.
Different power cable colors by country
When connecting an external power cable, be sure to match the colors of its wires with those of the 3 wires inside the
product’s power cable. The meaning (Neutral, Live or Ground) of each wire color of the external power cable may differ
depending on the country.
–
Be sure to refer to the following table to correctly connect wires by the same meaning:
Neutral
Live
Ground
Region
Blue
Brown
Green/yellow
Others
White
Black
Green
or green/yellow
America
Blue
Brown
Green/yellow
Europe
Black
Red
Green/yellow
India
White
Black
Green
or green/yellow
Taiwan & Japan
–
The guide for OH85N/(LH85OHNSKGB/**) only applies when the product is used with an enclosure unit that has a
protective glass added to the front side.
English - 21