17
This document can not be used without Samsung’s authorization.
3. Disassembly and Reassembly
This document can not be used without Samsung’s authorization.
3-2 ASSY CONTROL BOX
WARNING
Disconnect power before servicing the range. Replace all panels before operating range. Failure to
do so can result in death or electrical shock.
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
Shut off gas supply to the range before servicing. Check all gas lines and fittings for leaks before operating
the range . Replace all panels before operating range . Failure to do so can result in death or personal
injury from explosion, fire, or asphyxiation.
CAUTION
When you work on the gas range, be careful when handling sheet metal parts . Sharp edges may be
present, and you can cut yourself if you are not careful .
Explanation Photo
Explanation
2
3
3
3
2
2
2
2
Assy Wire Main
Disconnect the wire
(This Position)
1 . Remove 6 Knobs from the Assy Control
Box .
2 . Remove 2 screws from the each 5 Holder
Knobs except for Holder Knob Warmer .
(Total 10 pcs)
3 . Open the Door and Remove 4 screws
from the bottom of Assy Control Box .
4 . Lift the Assy Control Box slightly to
separate from the range . (Assy Wire Main
is still connected to the Assy Display of
Assy Control Box)
5 . Disconnect 3 wire connectors from the
Assy Display(PCB) .
6 . Remove the Assy Control Box from the
range .