4. Troubleshooting
This document can not be used without Samsung’s authorization.
Failure Display Codes
Safety Error
FAILURE
CODE
CAUSE
SOLUTION
C-d0
Shorted Key
(Key pad is pressed for
1 minutes .)
1 . Check the assy ITO glass FPCB to make sure it is properly
connected with PCB .
2 . Disconnect the assy ITO glass FPCB .
Check the FPCB and PCB for short circuits .
3 . If there is no problem with connector on main PCB and
membrane harness, replace the PCB .
C-d1
Door locking error
(Door lock in wrong
position after 1 minute .)
1 . Disconnect electrical power to the range .
Remove the rear cover panel . Make sure the wiring harness is
properly connected to the motorized door lock assembly .
2 . Check motorized door lock assembly for proper operating
resistance .
3 . With operating door lockout, measure the voltage of connector
on harness which is linked with door lock motor .
(Normal : Voltage : AC 120V)
4 . Check the door locking switch to make sure it is working
properly .