4. Troubleshooting
This document can not be used without Samsung’s authorization.
4. Troubleshooting
Check code
Failure
code
CAUSE
SOLUTION
C-d0
This code occurs if
the keys are shorted
.
1
.
Check whether keypad cable is inserted into connector
on sub pcb
.
2
.
Check for shorts between Sub PCB and the connector, or the
keypad and the cable
.
3
.
if no faults are found with Sub PCB connector and the keypad
cable replace the Sub PCB
.
C-d1
This code occurs if the
door lock is mispositioned
.
1
.
Disconnect power
.
Check whether harness has been connected
with door lock switch and motor
.
2
.
Confirm whether resistance value of door lock motor
is
correct
.
Normal value should be 1600
~ 2200 Ω at the room
temperature
.
3
.
Operate door lock, measure voltage at the plug supplying power
to the door lock motor
.
(normal voltage : AC 120V)
4
.
Check whether door locking switch is working normally
.
C-F0
This code occurs if communication
between the Main and Sub PCB is
interrupted
.
1
.
Check whether connector on main pcb has been inserted
correctly
.
2
.
Check whether connector on sub pcb has been inserted
correctly
.
3
.
If no issue with connector on Main and Sub PCBs has been
detected replace Main PCB
.
4-1 Failure Display Codes
1
.
Touch
FLEX
UPPER
and
FLEX LOWER
for 5 seconds
.
Information is displayed on screen
.
2
.
Touch
Error_Disp
.
The latest 5 check codes can be checked on display
.
3
.
Touch
FLEX UPPER
and
FLEX LOWER
for 5 seconds
to return to normal display mode
.
Cavity_1
Upper
Lower
ETC
Relay_1
Relay_2
Install TestS
team Use Clear
Error_Disp
U_Mode
U_Desired_TempU
_Preheat
U_FanSpeedP
owerLV
U_StageU
_Current_tempU
_Current_AD
Cavity_2
Cavity_1
Upper
Lower
ETC
Relay_1
Relay_2
Install TestS
team Use Clear
Error_Disp
Error1
Error5
Error2
Error3
Error4
Cavity_2