English 19
Installation instructions
Step 7. Check the ignition of cooktop burners
Check the operation of all cooktop burners after the cooktop has been installed
and assembled, gas supply lines have been carefully checked for leaks, and
electrical power cord has been plugged in.
Lite
MED
HI
LO
OFF
2
1
To turn on a cooktop burner
1.
Push in and turn the control knob for that
cooktop burner to the Lite position. The
“clicking” sound indicates the electronic
ignition system is operating properly. The
burner will light in about 4 seconds, after
the air has been purged from the supply
line .
2.
After the burner lights, turn the control
knob to the desired setting. The “clicking”
sound will stop and the flame height will
change from Max. to Min. during turning
the control knob.
3.
Repeat steps 1 and 2 to check the
operation of each cooktop burner in
succession.
NOTE
•
If the burner does not light within 4 seconds, turn the knob off and wait one
minute before trying again.
•
When you push in and turn the control knob, all spark igniters will make a series
of sparks, but only the burner turned to Lite will light.
Step 8. Checking the flame quality
All combustion flames need to be visually checked to determine their flame
quality.
CAUTION
If you attempt to measure the flame, please use caution. Burns could result.
2
3
1
1.
Soft blue flames
—Normal for natural gas
operation.
2.
Yellow tips on outer cones
—Normal for
LP gas operation.
3.
Yellow flames
—Abnormal for any gas
operation; call for service.
NOTE
If burner flame looks like 3, the cooktop
should not be used until it is serviced. Call
for service. Normal burner flames shall look
like 1 or 2, depending on the gas type you
use.
Install_NA30R5310FG_AA_DG68-01133A-00_EN.indd 19
2019-04-12 12:13:37