ENGLISH-19
03
O
tHE
rS
6)* Setting is available when there is only 1 indoor unit connection and while the indoor unit operation is not operating .
7)* You can see no .0(no use) and no .1(use) while mode master indoor unit setting .
For the mode master indoor unit setting, select the no .1(use) . And you can release the mode master unit setting
by selecting the no .2(release) .
8)* Power master reset is a setting needed to supply optimized power to wired remote controller when multiple indoor units
are connected to wired remote controller in a group .
the example of installation/service mode setting
1 . Press the top right corner (hidden button) of the display for more than 3 seconds
and drop it . Then you can press
[ + ]/[ - ]
buttons and select No .3 and press
[ OK ]
button .
- Main menu will be displayed . Press
[ + ]/[ - ]
buttons and select No .1 .
2 . Press
[ Mode ]
button to select the number you will set .
- Press
[ + ]/[ - ]
buttons and select No .1 .
3 . Press
[ Mode ]
button to enter the data setting stage .
- When you enter the setting stage, the current setting value will be displayed .
4 . Press
[ + ]/[ - ]
buttons to select No .1
- The wired remote controller option is set from both cooling and heating to
cooling only .
5 . Press the
[ Fan ]
button to select page No .2, then Press
[ + ]/[ - ]
buttons to select
No .0
- The wired remote controller option is set to no use of wireless remote controller .
6 . Press the
[ OK ]
button to save the current settings .
- Press the
[ Cancel ]
button for more than three seconds to exit to normal mode
without saving settings .
SOL 터치간단유선 유럽향 IM_EN_DB68-08073A-00.indd 19
2018-10-11 오후 3:35:07